Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1995
Principal Product Multi-Layered Printed Circuit Boards
NAICS n/a
SIC 3672 - Printed Circuit Boards
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 44,000
Annual Production 600,000 Pieces
Production Hrs. Annual 6,864
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $362,256 4,356,096 kWh $0.08
TOTAL ENERGY COSTS $370,910
RECOMMENDED SAVINGS* $25,117 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,717
#|Description Savings
Cost
Status Electricity Usage Water Disposal Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Water Disposal Other Liquid (haz) Solid Waste (non-haz)
$ kWh $ Tgal $ gal $ lb
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$8,690
Cost:
$8,500
$8,690 98,476 - - - - - - $8,690
98,476
kWh
-
-
Tgal
-
-
gal
-
-
lb
02: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE Savings:
$3,798
Cost:
$4,900
$3,798 61,254 - - - - - - $3,798
61,254
kWh
-
-
Tgal
-
-
gal
-
-
lb
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$948
Cost:
$238
$948 13,775 - - - - - - $948
13,775
kWh
-
-
Tgal
-
-
gal
-
-
lb
04: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$765
Cost:
$1,600
$765 8,499 - - - - - - $765
8,499
kWh
-
-
Tgal
-
-
gal
-
-
lb
05: 2.2223 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF Savings:
$608
Cost:
-
$608 9,672 - - - - - - $608
9,672
kWh
-
-
Tgal
-
-
gal
-
-
lb
06: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,654
Cost:
$305
$1,654 15,240 - - - - - - $1,654
15,240
kWh
-
-
Tgal
-
-
gal
-
-
lb
07: 3.6112 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME Savings:
$2,000
Cost:
$2,000
- - - - $2,000 5,000 - - -
-
kWh
-
-
Tgal
$2,000
5,000
gal
-
-
lb
08: 3.4113 TREAT AND REUSE RINSE WATERS Savings:
$1,893
Cost:
$300
- - $1,893 312,500 - - - - -
-
kWh
$1,893
312,500
Tgal
-
-
gal
-
-
lb
09: 3.1244 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS Savings:
$2,400
Cost:
$500
- - - - $2,400 1,663 - - -
-
kWh
-
-
Tgal
$2,400
1,663
gal
-
-
lb
10: 3.5241 SELL USED PLATES TO AN ALUMINUM RECYCLER Savings:
$2,361
Cost:
-
- - - - - - $2,361 29,523 -
-
kWh
-
-
Tgal
-
-
gal
$2,361
29,523
lb
TOTAL RECOMMENDED Savings:
$25,117
Cost:
$18,343
$16,463 206,916 $1,893 312,500 $4,400 6,663 $2,361 29,523 $16,463
206,916
kWh
$1,893
312,500
Tgal
$4,400
6,663
gal
$2,361
29,523
lb
TOTAL IMPLEMENTED Savings:
$11,717
Cost:
$10,405
$11,717 131,887 - - - - - - $11,717
131,887
kWh
-
-
Tgal
-
-
gal
-
-
lb
Savings
Cost
$ kWh $ Tgal $ gal $ lb
Electricity Usage Water Disposal Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Water Disposal Other Liquid (haz) Solid Waste (non-haz)