Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1995 |
Principal Product | Multi-Layered Printed Circuit Boards |
NAICS | n/a |
SIC | 3672 - Printed Circuit Boards |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 44,000 |
Annual Production | 600,000 Pieces |
Production Hrs. Annual | 6,864 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $362,256 | 4,356,096 | kWh | $0.08 |
TOTAL ENERGY COSTS | $370,910 | |||
RECOMMENDED SAVINGS* | $25,117 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,717 |
#|Description |
Savings Cost |
Status | Electricity Usage | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | Tgal | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $8,690 Cost: $8,500 |
$8,690 | 98,476 | - | - | - | - | - | - |
$8,690 98,476 kWh |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE |
Savings: $3,798 Cost: $4,900 |
$3,798 | 61,254 | - | - | - | - | - | - |
$3,798 61,254 kWh |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $948 Cost: $238 |
$948 | 13,775 | - | - | - | - | - | - |
$948 13,775 kWh |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $765 Cost: $1,600 |
$765 | 8,499 | - | - | - | - | - | - |
$765 8,499 kWh |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2223 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF |
Savings: $608 Cost: - |
$608 | 9,672 | - | - | - | - | - | - |
$608 9,672 kWh |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,654 Cost: $305 |
$1,654 | 15,240 | - | - | - | - | - | - |
$1,654 15,240 kWh |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6112 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME |
Savings: $2,000 Cost: $2,000 |
- | - | - | - | $2,000 | 5,000 | - | - |
- - kWh |
- - Tgal |
$2,000 5,000 gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $1,893 Cost: $300 |
- | - | $1,893 | 312,500 | - | - | - | - |
- - kWh |
$1,893 312,500 Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.1244 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS |
Savings: $2,400 Cost: $500 |
- | - | - | - | $2,400 | 1,663 | - | - |
- - kWh |
- - Tgal |
$2,400 1,663 gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5241 SELL USED PLATES TO AN ALUMINUM RECYCLER |
Savings: $2,361 Cost: - |
- | - | - | - | - | - | $2,361 | 29,523 |
- - kWh |
- - Tgal |
- - gal |
$2,361 29,523 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,117 Cost: $18,343 |
$16,463 | 206,916 | $1,893 | 312,500 | $4,400 | 6,663 | $2,361 | 29,523 | $16,463 206,916 kWh |
$1,893 312,500 Tgal |
$4,400 6,663 gal |
$2,361 29,523 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,717 Cost: $10,405 |
$11,717 | 131,887 | - | - | - | - | - | - | $11,717 131,887 kWh |
- - Tgal |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | Tgal | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) |