Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1997 |
Principal Product | Paints, Thinners, and coatings |
NAICS | n/a |
SIC | 2851 - Paints And Allied Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 272,500 |
Annual Production | 2,800 Thousand Gallons |
Production Hrs. Annual | 6,000 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $183,164 | 3,227,433 | kWh | $0.06 |
Electricity Demand | $88,121 | 9,090 | kW-months/year | $9.69 |
Natural Gas | $12,239 | 2,279 | MMBtu | $5.37 |
TOTAL ENERGY COSTS | $283,524 | |||
RECOMMENDED SAVINGS* | $1,218,556 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,172,356 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,603 Cost: $500 |
$2,689 | 47,186 | $914 | 94 | - | - | - | - | - | - |
$2,689 47,186 kWh |
$914 94 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $4,017 Cost: $1,000 |
- | - | - | - | $4,017 | 735 | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,017 735 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $3,910 Cost: $500 |
- | - | - | - | $3,910 | 724 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,910 724 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $1,214 Cost: $2,500 |
- | - | - | - | $1,214 | 225 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,214 225 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.3125 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS |
Savings: $46,200 Cost: $100,000 |
- | - | - | - | - | - | $46,200 | 60,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$46,200 60,000 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.8224 CONVERT TO LESS TOXIC HYDROCARBON CLEANERS |
Savings: $14,130 Cost: - |
- | - | - | - | - | - | $14,130 | 13,500 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$14,130 13,500 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $1,145,482 Cost: $644,000 |
- | - | - | - | - | - | - | - | $1,145,482 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$1,145,482 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,218,556 Cost: $748,500 |
$2,689 | 47,186 | $914 | 94 | $9,141 | 1,684 | $60,330 | 73,500 | $1,145,482 | - | $2,689 47,186 kWh |
$914 94 kW-months/year |
$9,141 1,684 MMBtu |
$60,330 73,500 gal |
$1,145,482 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,172,356 Cost: $648,500 |
$2,689 | 47,186 | $914 | 94 | $9,141 | 1,684 | $14,130 | 13,500 | $1,145,482 | - | $2,689 47,186 kWh |
$914 94 kW-months/year |
$9,141 1,684 MMBtu |
$14,130 13,500 gal |
$1,145,482 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes |