Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2000 |
Principal Product | combustible ordinances |
NAICS | n/a |
SIC | 3483 - Ammunition, Exc. For Small Arms, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 240 |
Plant Area (Sq.Ft.) | 108,000 |
Annual Production | 600,000 Pieces |
Production Hrs. Annual | 4,200 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $436,048 | 6,618,406 | kWh | $0.07 |
Electricity Demand | $54,249 | 19,152 | kW-months/year | $2.83 |
Electricity Fees | $25,505 | - | $ | - |
Natural Gas | $160,412 | 94,741 | MMBtu | $1.69 |
TOTAL ENERGY COSTS | $707,856 | |||
RECOMMENDED SAVINGS* | $428,143 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $61,356 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2422 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM |
Savings: $21,910 Cost: $10,250 |
- | - | - | - | $21,910 | 12,965 | - | - | - | - |
- - kWh |
- - kW-months/year |
$21,910 12,965 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2422 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM |
Savings: $13,294 Cost: $11,825 |
- | - | - | - | $13,294 | 7,866 | - | - | - | - |
- - kWh |
- - kW-months/year |
$13,294 7,866 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $838 Cost: $1,880 |
$792 | 11,430 | $46 | 16 | - | - | - | - | - | - |
$792 11,430 kWh |
$46 16 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $171,427 Cost: $100,000 |
- | - | - | - | $45,427 | 26,880 | - | - | $126,000 | - |
- - kWh |
- - kW-months/year |
$45,427 26,880 MMBtu |
- - Tgal |
$126,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $25,314 Cost: $100,000 |
- | - | - | - | - | - | $25,314 | 24,390,186 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$25,314 24,390,186 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $188,160 Cost: $200,000 |
- | - | - | - | - | - | - | - | $188,160 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$188,160 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $7,200 Cost: $3,000 |
- | - | - | - | - | - | - | - | $7,200 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$7,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $428,143 Cost: $426,955 |
$792 | 11,430 | $46 | 16 | $80,631 | 47,711 | $25,314 | 24,390,186 | $321,360 | - | $792 11,430 kWh |
$46 16 kW-months/year |
$80,631 47,711 MMBtu |
$25,314 24,390,186 Tgal |
$321,360 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $61,356 Cost: $123,955 |
$792 | 11,430 | $46 | 16 | $35,204 | 20,831 | $25,314 | 24,390,186 | - | - | $792 11,430 kWh |
$46 16 kW-months/year |
$35,204 20,831 MMBtu |
$25,314 24,390,186 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |