Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2001 |
Principal Product | naval ship repairs |
NAICS | n/a |
SIC | 3731 - Ship Building And Repairing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 230,000 |
Annual Production | 50 Pieces |
Production Hrs. Annual | 2,168 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $70,737 | 817,000 | kWh | $0.09 |
Electricity Demand | $24,440 | 3,055 | kW-months/year | $8.00 |
Electricity Fees | $520 | - | $ | - |
Natural Gas | $3,612 | 458 | MMBtu | $7.89 |
TOTAL ENERGY COSTS | $100,227 | |||
RECOMMENDED SAVINGS* | $20,675 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,267 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,388 Cost: $500 |
$2,901 | 33,499 | $1,487 | 186 | - | - | - | - | - | - |
$2,901 33,499 kWh |
$1,487 186 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,625 Cost: $13,000 |
$5,193 | 59,970 | $1,432 | 179 | - | - | - | - | - | - |
$5,193 59,970 kWh |
$1,432 179 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,234 Cost: $460 |
$817 | 9,430 | $417 | 52 | - | - | - | - | - | - |
$817 9,430 kWh |
$417 52 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $1,874 Cost: $1,012 |
$1,087 | 12,546 | $787 | 98 | - | - | - | - | - | - |
$1,087 12,546 kWh |
$787 98 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $4,783 Cost: $12,500 |
- | - | - | - | - | - | $4,783 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$4,783 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7311 MAINTAIN MACHINES TO REDUCE LEAKS |
Savings: $1,771 Cost: - |
- | - | - | - | $833 | 375 | - | - | $938 | - |
- - kWh |
- - kW-months/year |
$833 375 lb |
- - $ |
$938 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,675 Cost: $27,472 |
$9,998 | 115,445 | $4,123 | 515 | $833 | 375 | $4,783 | - | $938 | - | $9,998 115,445 kWh |
$4,123 515 kW-months/year |
$833 375 lb |
$4,783 - $ |
$938 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,267 Cost: $1,972 |
$4,805 | 55,475 | $2,691 | 336 | $833 | 375 | - | - | $938 | - | $4,805 55,475 kWh |
$2,691 336 kW-months/year |
$833 375 lb |
- - $ |
$938 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (haz) | Administrative Changes | Ancillary Material Cost |