Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2002
Principal Product Milk and hay
NAICS n/a
SIC 2026 - Fluid Milk
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 871,000
Annual Production 12,000 Thousand Gallons
Production Hrs. Annual 7,200
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $466,787 5,485,431 kWh $0.09
Electricity Demand $40,436 14,494 kW-months/year $2.79
Electricity Fees $192 - $ -
Natural Gas $44,508 10,038 MMBtu $4.43
TOTAL ENERGY COSTS $567,761
RECOMMENDED SAVINGS* $273,230 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$168,158
Cost:
$56,000
$157,950 1,856,046 $10,208 3,712 - - $157,950
1,856,046
kWh
$10,208
3,712
kW-months/year
-
-
$
02: 2.7311 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE Savings:
$7,470
Cost:
$6,000
$5,936 69,751 $1,534 558 - - $5,936
69,751
kWh
$1,534
558
kW-months/year
-
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,224
Cost:
$5,000
$3,968 46,633 $256 93 - - $3,968
46,633
kWh
$256
93
kW-months/year
-
-
$
04: 2.7311 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE Savings:
$1,853
Cost:
-
$1,295 15,218 $558 203 - - $1,295
15,218
kWh
$558
203
kW-months/year
-
-
$
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$525
Cost:
$500
$446 5,242 $79 29 - - $446
5,242
kWh
$79
29
kW-months/year
-
-
$
06: 3.2176 INCREASE USE OF AUTOMATION Savings:
$91,000
Cost:
$75,000
- - - - $91,000 - -
-
kWh
-
-
kW-months/year
$91,000
-
$
TOTAL RECOMMENDED Savings:
$273,230
Cost:
$142,500
$169,595 1,992,890 $12,635 4,595 $91,000 - $169,595
1,992,890
kWh
$12,635
4,595
kW-months/year
$91,000
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $