Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2006 |
Principal Product | Aerospace hydraulic actuators |
NAICS | 333995 - Fluid Power Cylinder and Actuator Manufacturing |
SIC | 3593 - Fluid Power Cylinders & Actuators |
Sales | $100,000,000-$500,000,000 |
# of Employees | 1,400 |
Plant Area (Sq.Ft.) | 370,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 7,956 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,195,034 | 20,934,534 | kWh | $0.10 |
Electricity Demand | $476,773 | 47,648 | kW-months/year | $10.01 |
Natural Gas | $2,093 | 3,965 | MMBtu | $0.53 |
TOTAL ENERGY COSTS | $2,673,900 | |||
RECOMMENDED SAVINGS* | $610,425 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,974 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $212,485 Cost: $900,288 |
$134,847 | 1,285,490 | $77,638 | 7,756 | - | - |
$134,847 1,285,490 kWh |
$77,638 7,756 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $169,122 Cost: - |
- | - | - | - | $169,122 | - |
- - kWh |
- - kW-months/year |
$169,122 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $110,534 Cost: $160,385 |
$110,534 | 1,053,710 | - | - | - | - |
$110,534 1,053,710 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $82,170 Cost: $150,000 |
$82,170 | 783,321 | - | - | - | - |
$82,170 783,321 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $23,140 Cost: $18,110 |
$23,140 | 220,599 | - | - | - | - |
$23,140 220,599 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $12,974 Cost: $220 |
$11,472 | 109,359 | $1,502 | 150 | - | - |
$11,472 109,359 kWh |
$1,502 150 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $610,425 Cost: $1,229,003 |
$362,163 | 3,452,479 | $79,140 | 7,906 | $169,122 | - | $362,163 3,452,479 kWh |
$79,140 7,906 kW-months/year |
$169,122 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,974 Cost: $220 |
$11,472 | 109,359 | $1,502 | 150 | - | - | $11,472 109,359 kWh |
$1,502 150 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |