Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2007
Principal Product valves
NAICS 332911 - Industrial Valve Manufacturing
SIC 3491 - Industrial Valves
Sales $50,000,000-$100,000,000
# of Employees 350
Plant Area (Sq.Ft.) 120,000
Annual Production 1,500 Pieces
Production Hrs. Annual 6,000
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $378,757 3,927,212 kWh $0.10
Electricity Demand $126,252 9,037 kW-months/year $13.97
Natural Gas $23,199 2,263 MMBtu $10.25
TOTAL ENERGY COSTS $528,208
RECOMMENDED SAVINGS* $116,277 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$72,155
Cost:
$103,750
$69,588 721,875 $32,270 2,310 $(-29,703) (-28,978) $69,588
721,875
kWh
$32,270
2,310
kW-months/year
$(-29,703)
(-28,978)
MMBtu
02: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$33,374
Cost:
$226,540
$121,240 1,257,675 $35,134 2,515 $(-123,000) (-12,000) $121,240
1,257,675
kWh
$35,134
2,515
kW-months/year
$(-123,000)
(-12,000)
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$5,868
Cost:
$3,046
$5,868 60,873 - - - - $5,868
60,873
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,578
Cost:
-
$4,578 47,493 - - - - $4,578
47,493
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$302
Cost:
$200
$302 3,133 - - - - $302
3,133
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$116,277
Cost:
$333,536
$201,576 2,091,049 $67,404 4,825 $(-152,703) (-40,978) $201,576
2,091,049
kWh
$67,404
4,825
kW-months/year
$(-152,703)
(-40,978)
MMBtu