Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2014
Principal Product Hoists and Winches
NAICS 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $100,000,000-$500,000,000
# of Employees 237
Plant Area (Sq.Ft.) 105,000
Annual Production 500 Pieces
Production Hrs. Annual 5,250
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $135,423 1,828,010 kWh $0.07
Electricity Demand $102,294 4,279 kW-months/year $23.91
Electricity Fees $7,998 - $ -
Natural Gas $16,902 2,397 MMBtu $7.05
TOTAL ENERGY COSTS $262,617
RECOMMENDED SAVINGS* $183,012 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,662
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$102,356
Cost:
$456,500
$67,455 1,246,875 $71,730 3,000 $(-36,829) (-5,224) $67,455
1,246,875
kWh
$71,730
3,000
kW-months/year
$(-36,829)
(-5,224)
MMBtu
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$58,476
Cost:
$249,000
$46,284 624,609 $12,192 510 - - $46,284
624,609
kWh
$12,192
510
kW-months/year
-
-
MMBtu
03: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$13,051
Cost:
$52,333
$13,051 176,124 - - - - $13,051
176,124
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,662
Cost:
$300
$2,885 38,940 $777 33 - - $2,885
38,940
kWh
$777
33
kW-months/year
-
-
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,971
Cost:
$5,075
$1,440 19,431 $531 22 - - $1,440
19,431
kWh
$531
22
kW-months/year
-
-
MMBtu
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,686
Cost:
$4,500
$1,686 22,756 - - - - $1,686
22,756
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,176
Cost:
$3,050
$927 12,505 $249 10 - - $927
12,505
kWh
$249
10
kW-months/year
-
-
MMBtu
08: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$634
Cost:
$370
$634 8,562 - - - - $634
8,562
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$183,012
Cost:
$771,128
$134,362 2,149,802 $85,479 3,575 $(-36,829) (-5,224) $134,362
2,149,802
kWh
$85,479
3,575
kW-months/year
$(-36,829)
(-5,224)
MMBtu
TOTAL IMPLEMENTED Savings:
$3,662
Cost:
$300
$2,885 38,940 $777 33 - - $2,885
38,940
kWh
$777
33
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas