Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2014 |
Principal Product | Lighting Fixtures |
NAICS | 335122 - Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing |
SIC | 3646 - Commercial Lighting Fixtures |
Sales | <$500,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 193,000 |
Annual Production | 80,001 Pieces |
Production Hrs. Annual | 3,835 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $77,369 | 925,197 | kWh | $0.08 |
Electricity Demand | $83,587 | 3,877 | kW-months/year | $21.56 |
Electricity Fees | $12,251 | - | $ | - |
Natural Gas | $18,749 | 2,550 | MMBtu | $7.35 |
TOTAL ENERGY COSTS | $191,956 | |||
RECOMMENDED SAVINGS* | $23,833 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,419 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $7,747 Cost: $8,360 |
$4,286 | 51,276 | $3,461 | 161 |
$4,286 51,276 kWh |
$3,461 161 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,664 Cost: $12,000 |
$7,664 | 91,672 | - | - |
$7,664 91,672 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $4,939 Cost: $15,269 |
$2,733 | 32,691 | $2,206 | 102 |
$2,733 32,691 kWh |
$2,206 102 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,811 Cost: $8,510 |
$2,002 | 23,949 | $809 | 38 |
$2,002 23,949 kWh |
$809 38 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $434 Cost: $1,400 |
$252 | 2,996 | $182 | 8 |
$252 2,996 kWh |
$182 8 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $238 Cost: $200 |
$225 | 2,687 | $13 | 1 |
$225 2,687 kWh |
$13 1 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $23,833 Cost: $45,739 |
$17,162 | 205,271 | $6,671 | 309 | $17,162 205,271 kWh |
$6,671 309 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,419 Cost: $9,960 |
$4,763 | 56,959 | $3,656 | 170 | $4,763 56,959 kWh |
$3,656 170 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |