Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2015 |
Principal Product | Hand Bags |
NAICS | 316992 - Women's Handbag and Purse Manufacturing |
SIC | 3171 - Women's Hangbags and Purses |
Sales | $10,000,000-$50,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 110,000 |
Annual Production | 460,000 Pieces |
Production Hrs. Annual | 2,388 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $254,131 | 2,806,535 | kWh | $0.09 |
Electricity Demand | $241,878 | 11,249 | kW-months/year | $21.50 |
Electricity Fees | $31,668 | - | $ | - |
TOTAL ENERGY COSTS | $527,677 | |||
RECOMMENDED SAVINGS* | $24,806 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,964 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Consumption | Electricity Usage | Electricity Demand | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $9,509 Cost: $14,580 |
$4,861 | 53,711 | $4,648 | 216 | - | - |
$4,861 53,711 kWh |
$4,648 216 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7273 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM |
Savings: $8,026 Cost: $34,300 |
$4,795 | 52,984 | $4,369 | 203 | $(-1,138) | - |
$4,795 52,984 kWh |
$4,369 203 kW-months/year |
$(-1,138) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,823 Cost: $1,400 |
$2,628 | 29,031 | $1,195 | 56 | - | - |
$2,628 29,031 kWh |
$1,195 56 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,368 Cost: $3,042 |
$1,368 | 15,127 | - | - | - | - |
$1,368 15,127 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,141 Cost: $1,250 |
$520 | 5,751 | $621 | 29 | - | - |
$520 5,751 kWh |
$621 29 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $939 Cost: $200 |
$260 | 2,870 | $679 | 32 | - | - |
$260 2,870 kWh |
$679 32 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $24,806 Cost: $54,772 |
$14,432 | 159,474 | $11,512 | 535 | $(-1,138) | - | $14,432 159,474 kWh |
$11,512 535 kW-months/year |
$(-1,138) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,964 Cost: $2,650 |
$3,148 | 34,782 | $1,816 | 85 | - | - | $3,148 34,782 kWh |
$1,816 85 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Consumption | Electricity Usage | Electricity Demand | Water Consumption |