Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2020
Principal Product Server Cabinets
NAICS 332321 - Metal Window and Door Manufacturing
SIC 3444 - Sheet Metalwork
Sales $10,000,000-$50,000,000
# of Employees 86
Plant Area (Sq.Ft.) 58,000
Annual Production 21,000 Units
Production Hrs. Annual 4,335
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $99,033 815,130 kWh $0.12
Electricity Demand $33,030 2,804 kW-months/year $11.78
Electricity Fees $2,889 - $ -
Natural Gas $71,939 10,235 MMBtu $7.03
TOTAL ENERGY COSTS $206,891
RECOMMENDED SAVINGS* $20,185 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$11,809
Cost:
$30,150
$8,052 66,278 $3,757 319 $8,052
66,278
kWh
$3,757
319
kW-months/year
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,628
Cost:
$300
$3,201 26,331 $427 36 $3,201
26,331
kWh
$427
36
kW-months/year
03: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT Savings:
$3,037
Cost:
$2,560
$3,037 24,999 - - $3,037
24,999
kWh
-
-
kW-months/year
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,711
Cost:
-
$1,711 14,092 - - $1,711
14,092
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$20,185
Cost:
$33,010
$16,001 131,700 $4,184 355 $16,001
131,700
kWh
$4,184
355
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand