IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2025
Principal Product Bioreactors
NAICS 325414 - Biological Product (except Diagnostic) Manufacturing
SIC 2836 - Biological Products Exc. Diagnostic
Sales $100,000,000-$500,000,000
# of Employees 150
Plant Area (Sq.Ft.) 240,000
Annual Production 100,000 Units
Production Hrs. Annual 5,633
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $879,531 2,906,458 kWh $0.30
Electricity Demand $364,831 3,743 kW-months/year $97.47
Electricity Fees $506,749 - $ -
Natural Gas $26,051 3,483 MMBtu $7.48
Other Gas $32,640 1 MMBtu $32,640.00
TOTAL ENERGY COSTS $1,809,802
RECOMMENDED SAVINGS* $978,814 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Primary Raw Material Electricity Usage Electricity Demand Natural Gas Primary Raw Material
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$614,791
Cost:
$395,505
$260,039 859,350 $354,752 3,640 - - - - $260,039
859,350
kWh
$354,752
3,640
kW-months/year
-
-
MMBtu
-
-
$
02: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL Savings:
$203,574
Cost:
$5,892
$(-19,102) (-63,126) $222,676 2,285 - - - - $(-19,102)
(-63,126)
kWh
$222,676
2,285
kW-months/year
-
-
MMBtu
-
-
$
03: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION Savings:
$23,739
Cost:
$46,406
$(-8,901) (-29,416) - - - - $32,640 - $(-8,901)
(-29,416)
kWh
-
-
kW-months/year
-
-
MMBtu
$32,640
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$58,983
Cost:
$101,750
$35,500 117,163 $6,892 71 $16,591 2,218 - - $35,500
117,163
kWh
$6,892
71
kW-months/year
$16,591
2,218
MMBtu
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,342
Cost:
$2,233
$1,799 5,944 $1,543 16 - - - - $1,799
5,944
kWh
$1,543
16
kW-months/year
-
-
MMBtu
-
-
$
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$74,386
Cost:
$209,425
$74,386 245,821 - - - - - - $74,386
245,821
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$978,814
Cost:
$761,211
$343,720 1,135,736 $585,863 6,011 $16,591 2,218 $32,640 - $343,720
1,135,736
kWh
$585,863
6,011
kW-months/year
$16,591
2,218
MMBtu
$32,640
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Primary Raw Material Electricity Usage Electricity Demand Natural Gas Primary Raw Material