Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2025 |
Principal Product | Bioreactors |
NAICS | 325414 - Biological Product (except Diagnostic) Manufacturing |
SIC | 2836 - Biological Products Exc. Diagnostic |
Sales | $100,000,000-$500,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 240,000 |
Annual Production | 100,000 Units |
Production Hrs. Annual | 5,633 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $879,531 | 2,906,458 | kWh | $0.30 |
Electricity Demand | $364,831 | 3,743 | kW-months/year | $97.47 |
Electricity Fees | $506,749 | - | $ | - |
Natural Gas | $26,051 | 3,483 | MMBtu | $7.48 |
Other Gas | $32,640 | 1 | MMBtu | $32,640.00 |
TOTAL ENERGY COSTS | $1,809,802 | |||
RECOMMENDED SAVINGS* | $978,814 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $614,791 Cost: $395,505 |
$260,039 | 859,350 | $354,752 | 3,640 | - | - | - | - |
$260,039 859,350 kWh |
$354,752 3,640 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $203,574 Cost: $5,892 |
$(-19,102) | (-63,126) | $222,676 | 2,285 | - | - | - | - |
$(-19,102) (-63,126) kWh |
$222,676 2,285 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $23,739 Cost: $46,406 |
$(-8,901) | (-29,416) | - | - | - | - | $32,640 | - |
$(-8,901) (-29,416) kWh |
- - kW-months/year |
- - MMBtu |
$32,640 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $58,983 Cost: $101,750 |
$35,500 | 117,163 | $6,892 | 71 | $16,591 | 2,218 | - | - |
$35,500 117,163 kWh |
$6,892 71 kW-months/year |
$16,591 2,218 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,342 Cost: $2,233 |
$1,799 | 5,944 | $1,543 | 16 | - | - | - | - |
$1,799 5,944 kWh |
$1,543 16 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $74,386 Cost: $209,425 |
$74,386 | 245,821 | - | - | - | - | - | - |
$74,386 245,821 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $978,814 Cost: $761,211 |
$343,720 | 1,135,736 | $585,863 | 6,011 | $16,591 | 2,218 | $32,640 | - | $343,720 1,135,736 kWh |
$585,863 6,011 kW-months/year |
$16,591 2,218 MMBtu |
$32,640 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material |