Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2001
Principal Product calf milk replacer
NAICS n/a
SIC 2023 - Dry, Condensed, Evaporated Products
Sales $10,000,000-$50,000,000
# of Employees 45
Plant Area (Sq.Ft.) 76,000
Annual Production 17,000 Tons
Production Hrs. Annual 2,340
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $98,061 883,888 kWh $0.11
Natural Gas $2,530 248 MMBtu $10.20
TOTAL ENERGY COSTS $120,967
RECOMMENDED SAVINGS* $23,877 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $22,182
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,206
Cost:
-
$1,206 12,843 - - $1,206
12,843
kWh
-
-
$
02: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT Savings:
$5,816
Cost:
$5,705
$5,816 (-21,804) - - $5,816
(-21,804)
kWh
-
-
$
03: 2.2611 MODERATE COOLING TOWER OUTLET TEMPERATURE Savings:
$415
Cost:
$406
$415 3,749 - - $415
3,749
kWh
-
-
$
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$529
Cost:
$840
$529 4,774 - - $529
4,774
kWh
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,695
Cost:
$11,140
$1,695 15,312 - - $1,695
15,312
kWh
-
-
$
06: 4.132 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST Savings:
$14,216
Cost:
$507
- - $14,216 - -
-
kWh
$14,216
-
$
TOTAL RECOMMENDED Savings:
$23,877
Cost:
$18,598
$9,661 14,874 $14,216 - $9,661
14,874
kWh
$14,216
-
$
TOTAL IMPLEMENTED Savings:
$22,182
Cost:
$7,458
$7,966 (-438) $14,216 - $7,966
(-438)
kWh
$14,216
-
$