IAC logo
IAC Assessment: SF0220
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0220
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2001
Principal Product Epoxy adhesives
NAICS n/a
SIC 2891 - Adhesives And Sealants
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 38,000
Annual Production 0 Units
Production Hrs. Annual 6,000
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $429,266 4,599,234 kWh $0.09
Natural Gas $147,744 24,897 MMBtu $5.93
TOTAL ENERGY COSTS $597,280
RECOMMENDED SAVINGS* $82,709 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $52,192
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.5123 REDUCE FLUID FLOW RATES Savings:
$51,887
Cost:
$240
- - $51,887 8,750 -
-
kWh
$51,887
8,750
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$924
Cost:
-
$924 9,945 - - $924
9,945
kWh
-
-
MMBtu
03: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$9,165
Cost:
$2,491
$9,165 98,550 - - $9,165
98,550
kWh
-
-
MMBtu
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$305
Cost:
$257
$305 3,278 - - $305
3,278
kWh
-
-
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,154
Cost:
$3,275
$3,154 36,281 - - $3,154
36,281
kWh
-
-
MMBtu
06: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$15,604
Cost:
$30,000
$15,604 230,400 - - $15,604
230,400
kWh
-
-
MMBtu
07: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$1,670
Cost:
$4,200
$1,670 17,955 - - $1,670
17,955
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$82,709
Cost:
$40,463
$30,822 396,409 $51,887 8,750 $30,822
396,409
kWh
$51,887
8,750
MMBtu
TOTAL IMPLEMENTED Savings:
$52,192
Cost:
$497
$305 3,278 $51,887 8,750 $305
3,278
kWh
$51,887
8,750
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas