IAC logo
IAC Assessment: SF0450
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0450
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2014
Principal Product Wine
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $10,000,000-$50,000,000
# of Employees 35
Plant Area (Sq.Ft.) 305,000
Annual Production 4,800,000 Pieces
Production Hrs. Annual 3,783
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $139,376 1,514,918 kWh $0.09
Electricity Demand $110,453 4,947 kW-months/year $22.33
Electricity Fees $7,960 - $ -
Natural Gas $31,803 3,947 MMBtu $8.06
TOTAL ENERGY COSTS $289,592
RECOMMENDED SAVINGS* $77,624 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,013
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$6,757
Cost:
-
$735 7,241 - - $6,022 747 - - $735
7,241
kWh
-
-
kW-months/year
$6,022
747
MMBtu
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,693
Cost:
$650
$2,693 26,517 - - - - - - $2,693
26,517
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$29,874
Cost:
$19,111
$29,874 294,176 - - - - - - $29,874
294,176
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$30,675
Cost:
$77,383
$8,885 87,493 $7,340 329 - - $14,450 - $8,885
87,493
kWh
$7,340
329
kW-months/year
-
-
MMBtu
$14,450
-
$
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$5,062
Cost:
$12,000
$4,085 40,224 $977 44 - - - - $4,085
40,224
kWh
$977
44
kW-months/year
-
-
MMBtu
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,563
Cost:
$11,811
$1,516 14,929 $1,047 47 - - - - $1,516
14,929
kWh
$1,047
47
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$77,624
Cost:
$120,955
$47,788 470,580 $9,364 419 $6,022 747 $14,450 - $47,788
470,580
kWh
$9,364
419
kW-months/year
$6,022
747
MMBtu
$14,450
-
$
TOTAL IMPLEMENTED Savings:
$12,013
Cost:
$12,461
$4,944 48,687 $1,047 47 $6,022 747 - - $4,944
48,687
kWh
$1,047
47
kW-months/year
$6,022
747
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes