Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2019 |
Principal Product | almonds |
NAICS | 311911 - Roasted Nuts and Peanut Butter Manufacturing |
SIC | 2068 - Salted And Roasted Nuts And Seeds |
Sales | $50,000,000-$100,000,000 |
# of Employees | 241 |
Plant Area (Sq.Ft.) | 290,000 |
Annual Production | 60,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,053,168 | 11,549,814 | kWh | $0.09 |
Electricity Demand | $364,677 | 23,952 | kW-months/year | $15.23 |
Natural Gas | $204,568 | 25,704 | MMBtu | $7.96 |
TOTAL ENERGY COSTS | $1,622,413 | |||
RECOMMENDED SAVINGS* | $508,453 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $96,672 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $146,044 Cost: - |
- | - | - | - | $146,044 | - | - | - |
- - kWh |
- - kW-months/year |
$146,044 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $29,680 Cost: $12,500 |
$29,680 | 325,507 | - | - | - | - | - | - |
$29,680 325,507 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $15,353 Cost: $5,947 |
$5,196 | 56,988 | - | - | - | - | $10,157 | 1,277 |
$5,196 56,988 kWh |
- - kW-months/year |
- - $ |
$10,157 1,277 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $27,526 Cost: $16,915 |
$31,896 | 349,814 | $7,293 | 480 | - | - | $(-11,663) | (-1,466) |
$31,896 349,814 kWh |
$7,293 480 kW-months/year |
- - $ |
$(-11,663) (-1,466) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $11,440 Cost: $7,616 |
$11,440 | 125,465 | - | - | - | - | - | - |
$11,440 125,465 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,101 Cost: $5,998 |
$8,101 | 88,849 | - | - | - | - | - | - |
$8,101 88,849 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $25,533 Cost: $34,367 |
$20,781 | 227,915 | $4,752 | 312 | - | - | - | - |
$20,781 227,915 kWh |
$4,752 312 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,565 Cost: $11,649 |
$5,343 | 58,601 | $1,222 | 80 | - | - | - | - |
$5,343 58,601 kWh |
$1,222 80 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $238,211 Cost: $1,672,972 |
$219,812 | 2,410,750 | $18,399 | 1,188 | - | - | - | - |
$219,812 2,410,750 kWh |
$18,399 1,188 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $508,453 Cost: $1,767,964 |
$332,249 | 3,643,889 | $31,666 | 2,060 | $146,044 | - | $(-1,506) | (-189) | $332,249 3,643,889 kWh |
$31,666 2,060 kW-months/year |
$146,044 - $ |
$(-1,506) (-189) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $96,672 Cost: $78,077 |
$80,541 | 883,325 | $5,974 | 392 | - | - | $10,157 | 1,277 | $80,541 883,325 kWh |
$5,974 392 kW-months/year |
- - $ |
$10,157 1,277 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |