Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2020
Principal Product Potato Chips, Corn Chips, and Similar Snacks
NAICS 311919 - Other Snack Food Manufacturing
SIC 2099 - Food Preparations, Nec
Sales >$500,000,000
# of Employees 1,000
Plant Area (Sq.Ft.) 540,000
Annual Production 165,924,726 Pounds
Production Hrs. Annual 8,760
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,829,947 27,273,502 kWh $0.07
Electricity Demand $842,282 49,752 kW-months/year $16.93
Electricity Fees $264,115 - $ -
Natural Gas $3,521,406 497,693 MMBtu $7.08
TOTAL ENERGY COSTS $6,457,750
RECOMMENDED SAVINGS* $162,061 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $118,378
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,941
Cost:
-
$5,781 86,155 - - - - $(-840) - $5,781
86,155
kWh
-
-
kW-months/year
-
-
MMBtu
$(-840)
-
$
02: 2.3321 USE STEAM PRESSURE REDUCTION TO GENERATE POWER Savings:
$98,999
Cost:
$34,416
- - - - $98,999 13,961 - - -
-
kWh
-
-
kW-months/year
$98,999
13,961
MMBtu
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,186
Cost:
$525
$1,186 17,681 - - - - - - $1,186
17,681
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$9,252
Cost:
$4,542
$9,252 137,880 - - - - - - $9,252
137,880
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,759
Cost:
$2,995
$4,759 70,928 - - - - - - $4,759
70,928
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$282
Cost:
$379
- - - - $282 40 - - -
-
kWh
-
-
kW-months/year
$282
40
MMBtu
-
-
$
07: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$30,342
Cost:
$50,211
- - - - $30,342 4,279 - - -
-
kWh
-
-
kW-months/year
$30,342
4,279
MMBtu
-
-
$
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$3,149
Cost:
$6,701
$3,149 46,925 - - - - - - $3,149
46,925
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$145
Cost:
$591
$145 2,157 - - - - - - $145
2,157
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
10: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT Savings:
$9,006
Cost:
$75,000
$9,857 146,895 $3,407 201 $(-4,258) (-600) - - $9,857
146,895
kWh
$3,407
201
kW-months/year
$(-4,258)
(-600)
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$162,061
Cost:
$175,360
$34,129 508,621 $3,407 201 $125,365 17,680 $(-840) - $34,129
508,621
kWh
$3,407
201
kW-months/year
$125,365
17,680
MMBtu
$(-840)
-
$
TOTAL IMPLEMENTED Savings:
$118,378
Cost:
$42,923
$19,937 297,120 - - $99,281 14,001 $(-840) - $19,937
297,120
kWh
-
-
kW-months/year
$99,281
14,001
MMBtu
$(-840)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes