Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2022
Principal Product Waste water
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $1,000,000-$5,000,000
# of Employees 10
Plant Area (Sq.Ft.) 770,000
Annual Production 421,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $215,552 1,335,718 kWh $0.16
Electricity Demand $90,955 2,388 kW-months/year $38.09
Electricity Fees $309,091 - $ -
TOTAL ENERGY COSTS $615,598
RECOMMENDED SAVINGS* $242,960 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $72,699
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$14,854
Cost:
-
$14,854 92,033 - - - - - - $14,854
92,033
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$53,458
Cost:
$172,352
$40,398 250,397 $13,060 343 - - - - $40,398
250,397
kWh
$13,060
343
kW-months/year
-
-
MMBtu
-
-
$
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$20,922
Cost:
$73,113
$20,922 129,629 - - - - - - $20,922
129,629
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,794
Cost:
$15,591
$3,794 23,505 - - - - - - $3,794
23,505
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,635
Cost:
$18,061
$2,721 16,858 $914 24 - - - - $2,721
16,858
kWh
$914
24
kW-months/year
-
-
MMBtu
-
-
$
06: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$95,881
Cost:
$341,026
$122,707 760,266 $39,800 1,045 $(-52,713) (-6,194) $(-13,913) - $122,707
760,266
kWh
$39,800
1,045
kW-months/year
$(-52,713)
(-6,194)
MMBtu
$(-13,913)
-
$
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$50,416
Cost:
$292,043
$50,416 312,365 - - - - - - $50,416
312,365
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$242,960
Cost:
$912,186
$255,812 1,585,053 $53,774 1,412 $(-52,713) (-6,194) $(-13,913) - $255,812
1,585,053
kWh
$53,774
1,412
kW-months/year
$(-52,713)
(-6,194)
MMBtu
$(-13,913)
-
$
TOTAL IMPLEMENTED Savings:
$72,699
Cost:
$325,695
$71,785 444,761 $914 24 - - - - $71,785
444,761
kWh
$914
24
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes