Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2023
Principal Product Anodizing, Plating
NAICS 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring
SIC 3471 - Plating And Polishing
Sales $1,000,000-$5,000,000
# of Employees 24
Plant Area (Sq.Ft.) 10,850
Annual Production 20,000 Units
Production Hrs. Annual 2,750
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $62,180 507,648 kWh $0.12
Electricity Demand $16,539 1,893 kW-months/year $8.74
Natural Gas $54,628 3,302 MMBtu $16.54
TOTAL ENERGY COSTS $133,347
RECOMMENDED SAVINGS* $40,035 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $24,446
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$16,621
Cost:
-
$16,621 135,680 - - - - $16,621
135,680
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.2514 COVER OPEN TANKS Savings:
$5,939
Cost:
$1,586
$5,939 48,482 - - - - $5,939
48,482
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$303
Cost:
$85
$230 1,874 $73 8 - - $230
1,874
kWh
$73
8
kW-months/year
-
-
MMBtu
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$3,351
Cost:
$1,069
$378 3,090 - - $2,973 180 $378
3,090
kWh
-
-
kW-months/year
$2,973
180
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$822
Cost:
$334
$748 6,103 $74 8 - - $748
6,103
kWh
$74
8
kW-months/year
-
-
MMBtu
06: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$863
Cost:
$905
- - - - $863 52 -
-
kWh
-
-
kW-months/year
$863
52
MMBtu
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,539
Cost:
$5,175
$3,539 28,889 - - - - $3,539
28,889
kWh
-
-
kW-months/year
-
-
MMBtu
08: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$2,486
Cost:
$9,050
$2,255 18,404 $231 26 - - $2,255
18,404
kWh
$231
26
kW-months/year
-
-
MMBtu
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$6,111
Cost:
$42,120
$6,111 49,882 - - - - $6,111
49,882
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$40,035
Cost:
$60,324
$35,821 292,404 $378 43 $3,836 232 $35,821
292,404
kWh
$378
43
kW-months/year
$3,836
232
MMBtu
TOTAL IMPLEMENTED Savings:
$24,446
Cost:
$11,443
$20,232 165,151 $378 43 $3,836 232 $20,232
165,151
kWh
$378
43
kW-months/year
$3,836
232
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas