Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2023
Principal Product Audio Speakers
NAICS 334310 - Audio and Video Equipment Manufacturing
SIC 3651 - Household Audio And Video Equipment
Sales $50,000,000-$100,000,000
# of Employees 300
Plant Area (Sq.Ft.) 49,000
Annual Production 5,000 Units
Production Hrs. Annual 2,384
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $385,087 1,447,554 kWh $0.27
Electricity Demand $24,590 2,757 kW-months/year $8.92
Electricity Fees $29,401 - $ -
Natural Gas $108,181 4,609 MMBtu $23.47
TOTAL ENERGY COSTS $547,259
RECOMMENDED SAVINGS* $208,590 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$24,945
Cost:
$4,958
$14,925 52,132 - - $10,020 427 - - - - $14,925
52,132
kWh
-
-
kW-months/year
$10,020
427
MMBtu
-
-
$
-
-
$
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$848
Cost:
$420
$733 2,561 $115 13 - - - - - - $733
2,561
kWh
$115
13
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$28,696
Cost:
$38,888
$28,696 100,231 - - - - - - - - $28,696
100,231
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,116
Cost:
$10,832
$1,975 6,897 - - - - $102 - $39 - $1,975
6,897
kWh
-
-
kW-months/year
-
-
MMBtu
$102
-
$
$39
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$233
Cost:
$1,287
$233 814 - - - - - - - - $233
814
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$21,756
Cost:
$37,440
- - - - - - $21,756 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$21,756
-
$
-
-
$
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$129,996
Cost:
$428,510
$129,996 454,056 - - - - - - - - $129,996
454,056
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$208,590
Cost:
$522,335
$176,558 616,691 $115 13 $10,020 427 $21,858 - $39 - $176,558
616,691
kWh
$115
13
kW-months/year
$10,020
427
MMBtu
$21,858
-
$
$39
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes Ancillary Material Cost