Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2025 |
Principal Product | Beer |
NAICS | 312120 - Breweries |
SIC | 2082 - Malt Beverages |
Sales | >$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 958,320 |
Annual Production | 1,200,000 BBL |
Production Hrs. Annual | 8,400 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $769,436 | 3,682,044 | kWh | $0.21 |
Electricity Demand | $646,771 | 15,962 | kW-months/year | $40.52 |
Natural Gas | $1,529,072 | 166,221 | MMBtu | $9.20 |
TOTAL ENERGY COSTS | $3,250,676 | |||
RECOMMENDED SAVINGS* | $362,533 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $28,680 Cost: - |
$29,880 | 142,968 | - | - | - | - | - | - | - | - | $(-1,200) | - |
$29,880 142,968 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$(-1,200) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $3,867 Cost: - |
$3,867 | 18,509 | - | - | - | - | - | - | - | - | - | - |
$3,867 18,509 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $2,640 Cost: - |
- | - | - | - | $3,740 | 407 | - | - | - | - | $(-1,100) | - |
- - kWh |
- - kW-months/year |
$3,740 407 MMBtu |
- - Tgal |
- - Tgal |
$(-1,100) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $12,083 Cost: $2,208 |
$12,083 | 57,813 | - | - | - | - | - | - | - | - | - | - |
$12,083 57,813 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $32,787 Cost: $17,210 |
$25,689 | 122,923 | $7,098 | 175 | - | - | - | - | - | - | - | - |
$25,689 122,923 kWh |
$7,098 175 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,235 Cost: $4,152 |
$1,202 | 5,754 | - | - | $2,033 | 221 | - | - | - | - | - | - |
$1,202 5,754 kWh |
- - kW-months/year |
$2,033 221 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $10,943 Cost: $20,376 |
$10,943 | 52,361 | - | - | - | - | - | - | - | - | - | - |
$10,943 52,361 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $32,940 Cost: $114,566 |
$32,940 | 157,606 | - | - | - | - | - | - | - | - | - | - |
$32,940 157,606 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4151 MINIMIZE WATER USAGE |
Savings: $3,105 Cost: $23,556 |
- | - | - | - | - | - | $619 | 639,000 | $2,486 | 639,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$619 639,000 Tgal |
$2,486 639,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $8,335 Cost: $80,990 |
$8,335 | 39,885 | - | - | - | - | - | - | - | - | - | - |
$8,335 39,885 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $223,918 Cost: $872,791 |
$223,918 | 1,071,379 | - | - | - | - | - | - | - | - | - | - |
$223,918 1,071,379 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $362,533 Cost: $1,135,849 |
$348,857 | 1,669,198 | $7,098 | 175 | $5,773 | 628 | $619 | 639,000 | $2,486 | 639,000 | $(-2,300) | - | $348,857 1,669,198 kWh |
$7,098 175 kW-months/year |
$5,773 628 MMBtu |
$619 639,000 Tgal |
$2,486 639,000 Tgal |
$(-2,300) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes |