Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2001
Principal Product Fuel, Cooling, and Lubricating Modules
NAICS n/a
SIC 3599 - Industrial Machinery, Nec
Sales n/a
# of Employees 250
Plant Area (Sq.Ft.) 180,000
Annual Production 0 Pieces
Production Hrs. Annual 4,680
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $160,089 2,947,500 kWh $0.05
Electricity Demand $71,538 8,090 kW-months/year $8.84
Natural Gas $166,600 225,300 MMBtu $0.74
TOTAL ENERGY COSTS $398,227
RECOMMENDED SAVINGS* $102,861 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,449
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$38,346
Cost:
$1,632
- - - - $38,346 5,182 -
-
kWh
-
-
kW-months/year
$38,346
5,182
MMBtu
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$25,154
Cost:
$7,162
- - - - $25,154 3,399 -
-
kWh
-
-
kW-months/year
$25,154
3,399
MMBtu
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$8,880
Cost:
$1,125
- - - - $8,880 1,200 -
-
kWh
-
-
kW-months/year
$8,880
1,200
MMBtu
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,743
Cost:
-
$1,619 32,380 $124 14 - - $1,619
32,380
kWh
$124
14
kW-months/year
-
-
MMBtu
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$444
Cost:
-
$444 8,880 - - - - $444
8,880
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$826
Cost:
$543
$826 15,300 - - - - $826
15,300
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$27,468
Cost:
$36,700
- - - - $27,468 3,711 -
-
kWh
-
-
kW-months/year
$27,468
3,711
MMBtu
TOTAL RECOMMENDED Savings:
$102,861
Cost:
$47,162
$2,889 56,560 $124 14 $99,848 13,492 $2,889
56,560
kWh
$124
14
kW-months/year
$99,848
13,492
MMBtu
TOTAL IMPLEMENTED Savings:
$11,449
Cost:
$1,668
$2,445 47,680 $124 14 $8,880 1,200 $2,445
47,680
kWh
$124
14
kW-months/year
$8,880
1,200
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas