Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2001 |
Principal Product | Candles |
NAICS | n/a |
SIC | 3999 - Manufacturing Industries, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 49 |
Plant Area (Sq.Ft.) | 36,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 1,920 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $21,847 | 364,120 | kWh | $0.06 |
Electricity Demand | $26,700 | 1,784 | kW-months/year | $14.97 |
Electricity Fees | $3,122 | - | $ | - |
Natural Gas | $43,837 | 5,745 | MMBtu | $7.63 |
TOTAL ENERGY COSTS | $95,506 | |||
RECOMMENDED SAVINGS* | $38,229 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,880 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $1,365 Cost: - |
- | - | - | - | - | - | $1,365 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,365 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,285 Cost: $38 |
- | - | - | - | $1,285 | 169 | - | - |
- - kWh |
- - kW-months/year |
$1,285 169 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $993 Cost: $123 |
- | - | - | - | $993 | 132 | - | - |
- - kWh |
- - kW-months/year |
$993 132 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $258 Cost: - |
$258 | 4,296 | - | - | - | - | - | - |
$258 4,296 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $264 Cost: $90 |
$261 | 4,355 | $3 | - | - | - | - | - |
$261 4,355 kWh |
$3 - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $34,064 Cost: $380,000 |
$21,847 | 364,120 | $22,723 | 1,783 | $(-10,506) | (-13,824) | - | - |
$21,847 364,120 kWh |
$22,723 1,783 kW-months/year |
$(-10,506) (-13,824) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,229 Cost: $380,251 |
$22,366 | 372,771 | $22,726 | 1,783 | $(-8,228) | (-13,523) | $1,365 | - | $22,366 372,771 kWh |
$22,726 1,783 kW-months/year |
$(-8,228) (-13,523) MMBtu |
$1,365 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,880 Cost: $213 |
$519 | 8,651 | $3 | - | $993 | 132 | $1,365 | - | $519 8,651 kWh |
$3 - kW-months/year |
$993 132 MMBtu |
$1,365 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |