Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2001 |
Principal Product | Copper Wire |
NAICS | n/a |
SIC | 3351 - Copper Rolling And Drawing |
Sales | n/a |
# of Employees | 190 |
Plant Area (Sq.Ft.) | 140,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 7,488 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,470,108 | 35,126,948 | kWh | $0.04 |
Electricity Demand | $153,399 | 50,160 | kW-months/year | $3.06 |
Electricity Fees | $333,607 | - | $ | - |
Natural Gas | $15,310 | 11,941 | MMBtu | $1.28 |
TOTAL ENERGY COSTS | $1,982,424 | |||
RECOMMENDED SAVINGS* | $191,498 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,501 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $7,264 Cost: $8,085 |
$7,264 | 172,966 | - | - | - | - | - | - |
$7,264 172,966 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $768 Cost: - |
$580 | 13,800 | $188 | 2 | - | - | - | - |
$580 13,800 kWh |
$188 2 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.631 INSTALL AN UNINTERUPTABLE POWER SUPPLY |
Savings: $153,410 Cost: $531,678 |
- | - | - | - | - | - | $153,410 | - |
- - kWh |
- - kW-months/year |
- - $ |
$153,410 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $12,307 Cost: $30,550 |
- | - | - | - | $12,307 | - | - | - |
- - kWh |
- - kW-months/year |
$12,307 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,845 Cost: $158 |
$3,845 | 91,559 | - | - | - | - | - | - |
$3,845 91,559 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,016 Cost: - |
$3,016 | 71,810 | - | - | - | - | - | - |
$3,016 71,810 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $10,888 Cost: $20,600 |
$10,888 | 259,227 | - | - | - | - | - | - |
$10,888 259,227 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $191,498 Cost: $591,071 |
$25,593 | 609,362 | $188 | 2 | $12,307 | - | $153,410 | - | $25,593 609,362 kWh |
$188 2 kW-months/year |
$12,307 - $ |
$153,410 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,501 Cost: $20,758 |
$15,313 | 364,586 | $188 | 2 | - | - | - | - | $15,313 364,586 kWh |
$188 2 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |