Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2002 |
Principal Product | Wood pallets and boxes |
NAICS | n/a |
SIC | 2448 - Wood Pallets And Skids |
Sales | $1,000,000-$5,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 61,509 |
Annual Production | 200,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $50,078 | 767,550 | kWh | $0.07 |
Electricity Demand | $46,510 | 3,417 | kW-months/year | $13.61 |
Other Gas | $920 | 60 | MMBtu | $15.33 |
TOTAL ENERGY COSTS | $97,508 | |||
RECOMMENDED SAVINGS* | $146,095 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $524 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Electricity Usage | Electricity Demand | Wood | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $217 Cost: $518 |
$217 | 3,103 | - | - | - | - |
$217 3,103 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $307 Cost: $38 |
$307 | 4,386 | - | - | - | - |
$307 4,386 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $442 Cost: $871 |
$442 | 6,317 | - | - | - | - |
$442 6,317 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,614 Cost: $1,875 |
$1,763 | 25,182 | $851 | 63 | - | - |
$1,763 25,182 kWh |
$851 63 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $33,055 Cost: $2,330 |
$11 | 162 | - | - | $33,044 | 68,262 |
$11 162 kWh |
- - kW-months/year |
$33,044 68,262 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3414 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT |
Savings: $109,460 Cost: $1,150,000 |
$53,729 | 767,560 | $55,731 | 3,417 | - | - |
$53,729 767,560 kWh |
$55,731 3,417 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $146,095 Cost: $1,155,632 |
$56,469 | 806,710 | $56,582 | 3,480 | $33,044 | 68,262 | $56,469 806,710 kWh |
$56,582 3,480 kW-months/year |
$33,044 68,262 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $524 Cost: $556 |
$524 | 7,489 | - | - | - | - | $524 7,489 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Electricity Usage | Electricity Demand | Wood |