Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2003
Principal Product Product safety and performance testing
NAICS n/a
SIC 8734 - Testing Laboratories
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 150,000
Annual Production 0 Units
Production Hrs. Annual 6,240
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $455,191 2,236,964 kWh $0.20
Natural Gas $109,967 14,948 MMBtu $7.36
TOTAL ENERGY COSTS $565,158
RECOMMENDED SAVINGS* $405,460 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR Savings:
$360,580
Cost:
$1,153,710
$360,580 2,236,064 - - - - $360,580
2,236,064
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$30,833
Cost:
$30,000
- - - - $30,833 4,195 -
-
kWh
-
-
kW-months/year
$30,833
4,195
MMBtu
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$7,864
Cost:
$4,382
$7,864 49,582 - - - - $7,864
49,582
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$3,295
Cost:
$6,573
- - $3,295 3,876 - - -
-
kWh
$3,295
3,876
kW-months/year
-
-
MMBtu
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$2,888
Cost:
$500
- - - - $2,888 393 -
-
kWh
-
-
kW-months/year
$2,888
393
MMBtu
TOTAL RECOMMENDED Savings:
$405,460
Cost:
$1,195,165
$368,444 2,285,646 $3,295 3,876 $33,721 4,588 $368,444
2,285,646
kWh
$3,295
3,876
kW-months/year
$33,721
4,588
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas