Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2003
Principal Product Boilers
NAICS 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing
SIC 4334 -
Sales $10,000,000-$50,000,000
# of Employees 202
Plant Area (Sq.Ft.) 140,000
Annual Production 2,500 Pieces
Production Hrs. Annual 4,420
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $195,170 1,925,933 kWh $0.10
Natural Gas $73,846 10,419 MMBtu $7.09
TOTAL ENERGY COSTS $271,716
RECOMMENDED SAVINGS* $15,202 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,038
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR Savings:
$12,003
Cost:
$16,100
- - - - $12,003 1,600 -
-
kWh
-
-
kW-months/year
$12,003
1,600
MMBtu
02: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION Savings:
$1,035
Cost:
$540
- - - - $1,035 146 -
-
kWh
-
-
kW-months/year
$1,035
146
MMBtu
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$580
Cost:
$2,033
- - - - $580 82 -
-
kWh
-
-
kW-months/year
$580
82
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$531
Cost:
$1,608
$165 5,501 $366 19 - - $165
5,501
kWh
$366
19
kW-months/year
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$468
Cost:
$748
- - - - $468 66 -
-
kWh
-
-
kW-months/year
$468
66
MMBtu
06: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$272
Cost:
$800
$121 4,036 $151 11 - - $121
4,036
kWh
$151
11
kW-months/year
-
-
MMBtu
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$218
Cost:
-
$101 3,359 $117 9 - - $101
3,359
kWh
$117
9
kW-months/year
-
-
MMBtu
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$95
Cost:
$70
$95 3,182 - - - - $95
3,182
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$15,202
Cost:
$21,899
$482 16,078 $634 39 $14,086 1,894 $482
16,078
kWh
$634
39
kW-months/year
$14,086
1,894
MMBtu
TOTAL IMPLEMENTED Savings:
$13,038
Cost:
$16,640
- - - - $13,038 1,746 -
-
kWh
-
-
kW-months/year
$13,038
1,746
MMBtu