Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2004 |
Principal Product | motors |
NAICS | 335312 - Motor and Generator Manufacturing |
SIC | 3621 - Motors And Generators |
Sales | $1,000,000-$5,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 68,000 |
Annual Production | 50,000 Pieces |
Production Hrs. Annual | 2,250 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $67,791 | 801,159 | kWh | $0.08 |
Electricity Demand | $49,753 | 3,591 | kW-months/year | $13.85 |
Natural Gas | $79,522 | 69,812 | MMBtu | $1.14 |
TOTAL ENERGY COSTS | $197,066 | |||
RECOMMENDED SAVINGS* | $45,054 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,289 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.311 SCHEDULE DELIVERIES ACCORDING TO DEMAND |
Savings: $4,883 Cost: - |
- | - | - | - | - | - | - | - | $4,883 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$4,883 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,000 Cost: - |
$1,066 | 12,600 | $934 | 67 | - | - | - | - | - | - |
$1,066 12,600 kWh |
$934 67 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $515 Cost: - |
$421 | 4,980 | $94 | 7 | - | - | - | - | - | - |
$421 4,980 kWh |
$94 7 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $325 Cost: - |
- | - | - | - | $325 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$325 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,426 Cost: $120 |
$761 | 9,000 | $665 | 48 | - | - | - | - | - | - |
$761 9,000 kWh |
$665 48 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,140 Cost: $400 |
$1,142 | 13,500 | $998 | 72 | - | - | - | - | - | - |
$1,142 13,500 kWh |
$998 72 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $31,815 Cost: $30,250 |
- | - | - | - | - | - | - | - | $31,815 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$31,815 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,950 Cost: $4,508 |
- | - | - | - | - | - | $1,950 | 222 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,950 222 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $45,054 Cost: $35,278 |
$3,390 | 40,080 | $2,691 | 194 | $325 | - | $1,950 | 222 | $36,698 | - | $3,390 40,080 kWh |
$2,691 194 kW-months/year |
$325 - $ |
$1,950 222 MMBtu |
$36,698 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,289 Cost: $520 |
$2,324 | 27,480 | $1,757 | 127 | $325 | - | - | - | $4,883 | - | $2,324 27,480 kWh |
$1,757 127 kW-months/year |
$325 - $ |
- - MMBtu |
$4,883 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes |