Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2013
Principal Product Low Pressure Sewer Systems and Condition Monitoring for Power Generation
NAICS 333911 - Pump and Pumping Equipment Manufacturing
SIC 3561 - Pumps And Pumping Equipment
Sales $50,000,000-$100,000,000
# of Employees 150
Plant Area (Sq.Ft.) 75,000
Annual Production 100,000 Pieces
Production Hrs. Annual 2,601
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $58,423 926,640 kWh $0.06
Electricity Demand $31,754 2,948 kW-months/year $10.77
Electricity Fees $7,476 - $ -
Natural Gas $13,976 2,234 MMBtu $6.26
TOTAL ENERGY COSTS $111,629
RECOMMENDED SAVINGS* $8,188 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,192
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$1,901
Cost:
-
- - - - - - $1,901 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$1,901
-
$
02: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES Savings:
$599
Cost:
-
- - - - - - $599 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$599
-
$
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$223
Cost:
-
$223 3,537 - - - - - - $223
3,537
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,291
Cost:
$1,750
$2,291 36,370 - - - - - - $2,291
36,370
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$373
Cost:
$1,418
$373 5,921 - - - - - - $373
5,921
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$1,775
Cost:
$5,400
$(-107) (-1,720) $(-12) (-1) $1,894 303 - - $(-107)
(-1,720)
kWh
$(-12)
(-1)
kW-months/year
$1,894
303
MMBtu
-
-
$
07: 2.7314 REDUCE VENTILATION AIR Savings:
$1,026
Cost:
$3,934
$132 2,100 - - $894 143 - - $132
2,100
kWh
-
-
kW-months/year
$894
143
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$8,188
Cost:
$12,502
$2,912 46,208 $(-12) (-1) $2,788 446 $2,500 - $2,912
46,208
kWh
$(-12)
(-1)
kW-months/year
$2,788
446
MMBtu
$2,500
-
$
TOTAL IMPLEMENTED Savings:
$4,192
Cost:
$1,750
$2,291 36,370 - - - - $1,901 - $2,291
36,370
kWh
-
-
kW-months/year
-
-
MMBtu
$1,901
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost