IAC logo
IAC Assessment: TN0116
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TN0116
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1982
Principal Product RAILCARS
NAICS n/a
SIC 3743 - Railroad Equipment
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 0
Annual Production 400 Pieces
Production Hrs. Annual 4,000
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $104,000 2,779,895 kWh $0.04
LPG $34,000 5,404 MMBtu $6.29
TOTAL ENERGY COSTS $138,000
RECOMMENDED SAVINGS* $6,449 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage LPG Electricity Usage LPG
$ kWh $ MMBtu
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,760
Cost:
$500
- - $4,760 743 -
-
kWh
$4,760
743
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,377
Cost:
-
$160 2,931 $1,217 190 $160
2,931
kWh
$1,217
190
MMBtu
03: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$312
Cost:
-
$(-6,600) (-249,121) $6,912 1,080 $(-6,600)
(-249,121)
kWh
$6,912
1,080
MMBtu
TOTAL RECOMMENDED Savings:
$6,449
Cost:
$500
$(-6,440) (-246,190) $12,889 2,013 $(-6,440)
(-246,190)
kWh
$12,889
2,013
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage LPG Electricity Usage LPG