Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1982
Principal Product RECYCLED SCRAP METAL
NAICS n/a
SIC 3312 - Blast Furnaces And Steel Mills
Sales n/a
# of Employees 42
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 2,470
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $14,246 211,606 kWh $0.07
Natural Gas $2,221 422 MMBtu $5.26
LPG $3,013 365 MMBtu $8.25
Other Energy $2,496 295 MMBtu $8.46
TOTAL ENERGY COSTS $21,976
RECOMMENDED SAVINGS* $2,453 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Other Energy Electricity Usage Natural Gas Other Energy
$ kWh $ MMBtu $ MMBtu
01: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT Savings:
$1,517
Cost:
$1,635
$(-979) (-14,654) - - $2,496 295 $(-979)
(-14,654)
kWh
-
-
MMBtu
$2,496
295
MMBtu
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$500
Cost:
$510
- - $500 95 - - -
-
kWh
$500
95
MMBtu
-
-
MMBtu
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$305
Cost:
$996
$(-337) (-4,982) $642 122 - - $(-337)
(-4,982)
kWh
$642
122
MMBtu
-
-
MMBtu
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$131
Cost:
-
$131 2,052 - - - - $131
2,052
kWh
-
-
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$2,453
Cost:
$3,141
$(-1,185) (-17,584) $1,142 217 $2,496 295 $(-1,185)
(-17,584)
kWh
$1,142
217
MMBtu
$2,496
295
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas Other Energy Electricity Usage Natural Gas Other Energy