IAC logo
IAC Assessment: TN0238
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TN0238
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1984
Principal Product MEN'S DRESS SLACKS
NAICS n/a
SIC 2325 - Men's and Boys' Separate Trousers and Slacks
Sales $10,000,000-$50,000,000
# of Employees 556
Plant Area (Sq.Ft.) 0
Annual Production 2,700,000 Pieces
Production Hrs. Annual 1,955
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $222,762 4,951,934 kWh $0.04
Natural Gas $35,156 7,028 MMBtu $5.00
TOTAL ENERGY COSTS $257,918
RECOMMENDED SAVINGS* $15,079 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,959
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$7,856
Cost:
-
$7,856 174,678 - - - - $7,856
174,678
kWh
-
-
MMBtu
-
-
$
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,292
Cost:
$794
$492 10,844 $800 160 - - $492
10,844
kWh
$800
160
MMBtu
-
-
$
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$956
Cost:
$140
$364 8,206 $592 118 - - $364
8,206
kWh
$592
118
MMBtu
-
-
$
04: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$1,287
Cost:
-
$1,287 28,722 - - - - $1,287
28,722
kWh
-
-
MMBtu
-
-
$
05: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE Savings:
$257
Cost:
-
$120 2,638 $137 27 - - $120
2,638
kWh
$137
27
MMBtu
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$510
Cost:
$253
$194 4,396 $316 63 - - $194
4,396
kWh
$316
63
MMBtu
-
-
$
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$707
Cost:
-
$707 15,826 - - - - $707
15,826
kWh
-
-
MMBtu
-
-
$
08: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES Savings:
$1,795
Cost:
$480
$481 10,844 - - $1,314 - $481
10,844
kWh
-
-
MMBtu
$1,314
-
$
09: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$165
Cost:
-
$36 879 $129 26 - - $36
879
kWh
$129
26
MMBtu
-
-
$
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$207
Cost:
$32
$207 4,689 - - - - $207
4,689
kWh
-
-
MMBtu
-
-
$
11: 2.2511 INSULATE BARE EQUIPMENT Savings:
$47
Cost:
$35
- - $47 9 - - -
-
kWh
$47
9
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$15,079
Cost:
$1,734
$11,744 261,722 $2,021 403 $1,314 - $11,744
261,722
kWh
$2,021
403
MMBtu
$1,314
-
$
TOTAL IMPLEMENTED Savings:
$5,959
Cost:
$1,446
$2,987 66,822 $1,658 331 $1,314 - $2,987
66,822
kWh
$1,658
331
MMBtu
$1,314
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes