Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 1986 |
Principal Product | REFINED PETROLEUM PRDTS. |
NAICS | n/a |
SIC | 2911 - Petroleum Refining |
Sales | $50,000,000-$100,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 63,000 Thousand Gallons |
Production Hrs. Annual | 8,736 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $126,387 | 2,763,482 | kWh | $0.05 |
Natural Gas | $175,896 | 47,189 | MMBtu | $3.73 |
Other Energy | $609,331 | 223,988 | MMBtu | $2.72 |
TOTAL ENERGY COSTS | $911,614 | |||
RECOMMENDED SAVINGS* | $252,170 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $187,685 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Gas | Electricity Usage | Natural Gas | Other Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $64,485 Cost: $105,000 |
- | - | $42,606 | 11,515 | $21,879 | 11,515 |
- - kWh |
$42,606 11,515 MMBtu |
$21,879 11,515 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $32,373 Cost: $4,500 |
- | - | $5,228 | 1,413 | $27,145 | 14,287 |
- - kWh |
$5,228 1,413 MMBtu |
$27,145 14,287 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $11,562 Cost: $150 |
- | - | $11,562 | 3,125 | - | - |
- - kWh |
$11,562 3,125 MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3416 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST |
Savings: $143,750 Cost: $40,000 |
$127,106 | 2,763,189 | - | - | $16,644 | 8,760 |
$127,106 2,763,189 kWh |
- - MMBtu |
$16,644 8,760 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $252,170 Cost: $149,650 |
$127,106 | 2,763,189 | $59,396 | 16,053 | $65,668 | 34,562 | $127,106 2,763,189 kWh |
$59,396 16,053 MMBtu |
$65,668 34,562 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $187,685 Cost: $44,650 |
$127,106 | 2,763,189 | $16,790 | 4,538 | $43,789 | 23,047 | $127,106 2,763,189 kWh |
$16,790 4,538 MMBtu |
$43,789 23,047 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Gas | Electricity Usage | Natural Gas | Other Gas |