Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 1999 |
Principal Product | Uniforms |
NAICS | n/a |
SIC | 2326 - Men's and Boys' Work Clothing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 488,000 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $23,267 | 788,980 | kWh | $0.03 |
Electricity Demand | $13,515 | 3,908 | kW-months/year | $3.46 |
Electricity Fees | $6,329 | - | $ | - |
Natural Gas | $42,738 | 6,593 | MMBtu | $6.48 |
TOTAL ENERGY COSTS | $85,849 | |||
RECOMMENDED SAVINGS* | $59,662 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $38,164 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $30,906 Cost: $3,200 |
- | - | - | - | - | - | $30,906 | 261,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$30,906 261,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $20,663 Cost: $16,000 |
- | - | - | - | - | - | - | - | $20,663 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$20,663 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $6,283 Cost: $3,000 |
$5,363 | 98,183 | - | - | $920 | 142 | - | - | - | - |
$5,363 98,183 kWh |
- - kW-months/year |
$920 142 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR |
Savings: $640 Cost: $1,250 |
$640 | 11,723 | - | - | - | - | - | - | - | - |
$640 11,723 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $493 Cost: $625 |
- | - | - | - | - | - | $493 | 9,250 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$493 9,250 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $342 Cost: - |
$242 | 4,396 | $100 | 2 | - | - | - | - | - | - |
$242 4,396 kWh |
$100 2 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $335 Cost: - |
$335 | 12,309 | - | - | - | - | - | - | - | - |
$335 12,309 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $59,662 Cost: $24,075 |
$6,580 | 126,611 | $100 | 2 | $920 | 142 | $31,399 | 270,250 | $20,663 | - | $6,580 126,611 kWh |
$100 2 kW-months/year |
$920 142 MMBtu |
$31,399 270,250 lb |
$20,663 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $38,164 Cost: $7,450 |
$6,338 | 122,215 | - | - | $920 | 142 | $30,906 | 261,000 | - | - | $6,338 122,215 kWh |
- - kW-months/year |
$920 142 MMBtu |
$30,906 261,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Raw Material |