Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2018 |
Principal Product | Cars |
NAICS | 336111 - Automobile Manufacturing |
SIC | 3711 - Motor Vehicles And Car Bodies |
Sales | >$500,000,000 |
# of Employees | 6,500 |
Plant Area (Sq.Ft.) | 4,500,000 |
Annual Production | 315,000 Units |
Production Hrs. Annual | 8,064 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $5,739,791 | 215,054,000 | kWh | $0.03 |
Electricity Demand | $3,372,002 | 454,194 | kW-months/year | $7.42 |
Natural Gas | $2,466,613 | 803,743 | MMBtu | $3.07 |
TOTAL ENERGY COSTS | $11,996,348 | |||
RECOMMENDED SAVINGS* | $326,729 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $145,597 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Electricity Usage | Electricity Demand | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS |
Savings: $76,685 Cost: $250,172 |
$76,685 | 2,873,165 | - | - | - | - |
$76,685 2,873,165 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $68,776 Cost: $32,000 |
$48,642 | 1,822,464 | $20,134 | 2,712 | - | - |
$48,642 1,822,464 kWh |
$20,134 2,712 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $68,707 Cost: $330,000 |
$68,707 | 2,574,261 | - | - | - | - |
$68,707 2,574,261 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS |
Savings: $38,635 Cost: $13,000 |
$38,635 | 1,447,545 | - | - | - | - |
$38,635 1,447,545 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4155 METER WASTE WATER |
Savings: $34,128 Cost: $1,900 |
- | - | - | - | $34,128 | 22,752 |
- - kWh |
- - kW-months/year |
$34,128 22,752 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $17,427 Cost: $79,168 |
$17,427 | 652,938 | - | - | - | - |
$17,427 652,938 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $9,248 Cost: $34,845 |
$6,056 | 226,829 | $3,192 | 430 | - | - |
$6,056 226,829 kWh |
$3,192 430 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,795 Cost: $16,665 |
$4,451 | 166,690 | $2,344 | 316 | - | - |
$4,451 166,690 kWh |
$2,344 316 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4113 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS |
Savings: $3,775 Cost: $5,000 |
$2,390 | 89,547 | $1,385 | 187 | - | - |
$2,390 89,547 kWh |
$1,385 187 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS |
Savings: $2,270 Cost: $1,720 |
$1,644 | 61,583 | $626 | 84 | - | - |
$1,644 61,583 kWh |
$626 84 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $283 Cost: $250 |
$283 | 10,591 | - | - | - | - |
$283 10,591 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $326,729 Cost: $764,720 |
$264,920 | 9,925,613 | $27,681 | 3,729 | $34,128 | 22,752 | $264,920 9,925,613 kWh |
$27,681 3,729 kW-months/year |
$34,128 22,752 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $145,597 Cost: $52,150 |
$89,950 | 3,370,147 | $21,519 | 2,899 | $34,128 | 22,752 | $89,950 3,370,147 kWh |
$21,519 2,899 kW-months/year |
$34,128 22,752 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Electricity Usage | Electricity Demand | Water Disposal |