IAC logo
IAC Assessment: TT0228
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TT0228
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tennessee Technological University
Assessment Year 2019
Principal Product Jackets and Bibs
NAICS 315220 - Men’s and Boys’ Cut and Sew Apparel Manufacturing
SIC 2326 - Men's and Boys' Work Clothing
Sales $50,000,000-$100,000,000
# of Employees 196
Plant Area (Sq.Ft.) 78,000
Annual Production 370,673 Units
Production Hrs. Annual 2,100
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $73,367 1,029,120 kWh $0.07
Electricity Demand $52,762 4,956 kW-months/year $10.65
Natural Gas $8,102 812 MMBtu $9.98
TOTAL ENERGY COSTS $135,944
RECOMMENDED SAVINGS* $17,320 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,882
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$7,113
Cost:
$17,840
$7,113 99,762 - - $7,113
99,762
kWh
-
-
kW-months/year
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$5,538
Cost:
$4,300
$4,235 59,404 $1,303 122 $4,235
59,404
kWh
$1,303
122
kW-months/year
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,880
Cost:
$100
$1,880 26,368 - - $1,880
26,368
kWh
-
-
kW-months/year
04: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$1,438
Cost:
$1,100
$1,438 20,168 - - $1,438
20,168
kWh
-
-
kW-months/year
05: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$1,351
Cost:
$1,100
$1,351 18,953 - - $1,351
18,953
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$17,320
Cost:
$24,440
$16,017 224,655 $1,303 122 $16,017
224,655
kWh
$1,303
122
kW-months/year
TOTAL IMPLEMENTED Savings:
$15,882
Cost:
$23,340
$14,579 204,487 $1,303 122 $14,579
204,487
kWh
$1,303
122
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand