IAC logo
IAC Assessment: TT0270
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TT0270
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tennessee Technological University
Assessment Year 2022
Principal Product Kayaks
NAICS 336612 - Boat Building
SIC 3732 - Boat Building And Repairing
Sales $10,000,000-$50,000,000
# of Employees 123
Plant Area (Sq.Ft.) 330,000
Annual Production 20,000 Units
Production Hrs. Annual 6,120
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $115,519 1,633,087 kWh $0.07
Electricity Demand $89,547 6,441 kW-months/year $13.90
Natural Gas $242,873 27,853 MMBtu $8.72
TOTAL ENERGY COSTS $447,939
RECOMMENDED SAVINGS* $23,832 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $18,829
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$10,427
Cost:
$2,000
- - $10,427 750 - - -
-
kWh
$10,427
750
kW-months/year
-
-
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$5,525
Cost:
$50
- - - - $5,525 634 -
-
kWh
-
-
kW-months/year
$5,525
634
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,877
Cost:
$2,770
$2,877 40,517 - - - - $2,877
40,517
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,829
Cost:
$40
$1,829 25,761 - - - - $1,829
25,761
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,201
Cost:
$2,240
$1,201 16,910 - - - - $1,201
16,910
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.9113 USE SOLAR HEAT FOR HEAT Savings:
$1,092
Cost:
$4,800
$1,092 15,376 - - - - $1,092
15,376
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$881
Cost:
$1,200
$881 12,414 - - - - $881
12,414
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$23,832
Cost:
$13,100
$7,880 110,978 $10,427 750 $5,525 634 $7,880
110,978
kWh
$10,427
750
kW-months/year
$5,525
634
MMBtu
TOTAL IMPLEMENTED Savings:
$18,829
Cost:
$4,820
$2,877 40,517 $10,427 750 $5,525 634 $2,877
40,517
kWh
$10,427
750
kW-months/year
$5,525
634
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas