Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tennessee Technological University
Assessment Year 2022
Principal Product Photopolymer Printing Plates
NAICS 323120 - Support Activities for Printing
SIC 2796 - Platemaking Services
Sales $50,000,000-$100,000,000
# of Employees 66
Plant Area (Sq.Ft.) 100,000
Annual Production 1,500,000 Units
Production Hrs. Annual 8,064
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $242,457 3,794,940 kWh $0.06
Electricity Demand $101,011 7,417 kW-months/year $13.62
Natural Gas $16,661 2,483 MMBtu $6.71
TOTAL ENERGY COSTS $366,548
RECOMMENDED SAVINGS* $62,764 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $9,105
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$51,568
Cost:
$201,200
$51,568 805,754 - - $51,568
805,754
kWh
-
-
kW-months/year
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,414
Cost:
$200
$6,414 100,212 - - $6,414
100,212
kWh
-
-
kW-months/year
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$2,091
Cost:
$200
$2,091 32,675 - - $2,091
32,675
kWh
-
-
kW-months/year
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,040
Cost:
$63
$1,580 24,679 $460 34 $1,580
24,679
kWh
$460
34
kW-months/year
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$651
Cost:
$1,500
$651 10,173 - - $651
10,173
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$62,764
Cost:
$203,163
$62,303 973,493 $460 34 $62,303
973,493
kWh
$460
34
kW-months/year
TOTAL IMPLEMENTED Savings:
$9,105
Cost:
$1,763
$8,644 135,064 $460 34 $8,644
135,064
kWh
$460
34
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand