Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tennessee Technological University
Assessment Year 2023
Principal Product Light-Duty Water Heaters
NAICS 335228 - Other Major Household Appliance Manufacturing
SIC 3639 - Household Appliances, Nec
Sales $100,000,000-$500,000,000
# of Employees 988
Plant Area (Sq.Ft.) 539,000
Annual Production 1,612,000 Units
Production Hrs. Annual 3,968
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,282,456 20,783,949 kWh $0.06
Electricity Demand $651,783 45,853 kW-months/year $14.21
Natural Gas $1,466,581 247,651 MMBtu $5.92
TOTAL ENERGY COSTS $3,400,820
RECOMMENDED SAVINGS* $93,192 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Water Usage Electricity Usage Electricity Demand Electricity Fees Water Usage
$ kWh $ kW-months/year $ $ $ Tgal
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$49,703
Cost:
$203,650
$49,703 805,540 - - - - - - $49,703
805,540
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$13,890
Cost:
$1,250
$13,890 225,124 - - - - - - $13,890
225,124
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$11,161
Cost:
$14,500
$11,161 180,900 - - - - - - $11,161
180,900
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
04: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$8,533
Cost:
$20,000
- - - - $8,533 - - - -
-
kWh
-
-
kW-months/year
$8,533
-
$
-
-
Tgal
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,428
Cost:
$1,950
$5,428 87,970 - - - - - - $5,428
87,970
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,512
Cost:
$6,000
$1,553 25,178 $959 67 - - - - $1,553
25,178
kWh
$959
67
kW-months/year
-
-
$
-
-
Tgal
07: 3.5132 REUSE RICH WHITE WATER IN OTHER APPLICATIONS Savings:
$1,230
Cost:
$1,820
- - - - - - $1,230 116 -
-
kWh
-
-
kW-months/year
-
-
$
$1,230
116
Tgal
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$735
Cost:
$750
$621 10,058 $114 8 - - - - $621
10,058
kWh
$114
8
kW-months/year
-
-
$
-
-
Tgal
TOTAL RECOMMENDED Savings:
$93,192
Cost:
$249,920
$82,356 1,334,770 $1,073 75 $8,533 - $1,230 116 $82,356
1,334,770
kWh
$1,073
75
kW-months/year
$8,533
-
$
$1,230
116
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ $ $ Tgal
Electricity Usage Electricity Demand Electricity Fees Water Usage Electricity Usage Electricity Demand Electricity Fees Water Usage