Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2023 |
Principal Product | Light-Duty Water Heaters |
NAICS | 335228 - Other Major Household Appliance Manufacturing |
SIC | 3639 - Household Appliances, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 988 |
Plant Area (Sq.Ft.) | 539,000 |
Annual Production | 1,612,000 Units |
Production Hrs. Annual | 3,968 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,282,456 | 20,783,949 | kWh | $0.06 |
Electricity Demand | $651,783 | 45,853 | kW-months/year | $14.21 |
Natural Gas | $1,466,581 | 247,651 | MMBtu | $5.92 |
TOTAL ENERGY COSTS | $3,400,820 | |||
RECOMMENDED SAVINGS* | $93,192 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Usage | Electricity Usage | Electricity Demand | Electricity Fees | Water Usage | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $49,703 Cost: $203,650 |
$49,703 | 805,540 | - | - | - | - | - | - |
$49,703 805,540 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $13,890 Cost: $1,250 |
$13,890 | 225,124 | - | - | - | - | - | - |
$13,890 225,124 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $11,161 Cost: $14,500 |
$11,161 | 180,900 | - | - | - | - | - | - |
$11,161 180,900 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $8,533 Cost: $20,000 |
- | - | - | - | $8,533 | - | - | - |
- - kWh |
- - kW-months/year |
$8,533 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,428 Cost: $1,950 |
$5,428 | 87,970 | - | - | - | - | - | - |
$5,428 87,970 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,512 Cost: $6,000 |
$1,553 | 25,178 | $959 | 67 | - | - | - | - |
$1,553 25,178 kWh |
$959 67 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5132 REUSE RICH WHITE WATER IN OTHER APPLICATIONS |
Savings: $1,230 Cost: $1,820 |
- | - | - | - | - | - | $1,230 | 116 |
- - kWh |
- - kW-months/year |
- - $ |
$1,230 116 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $735 Cost: $750 |
$621 | 10,058 | $114 | 8 | - | - | - | - |
$621 10,058 kWh |
$114 8 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $93,192 Cost: $249,920 |
$82,356 | 1,334,770 | $1,073 | 75 | $8,533 | - | $1,230 | 116 | $82,356 1,334,770 kWh |
$1,073 75 kW-months/year |
$8,533 - $ |
$1,230 116 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Usage | Electricity Usage | Electricity Demand | Electricity Fees | Water Usage |