Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2011 |
Principal Product | Communications Equipment |
NAICS | 334290 - Other Communications Equipment Manufacturing |
SIC | 3669 - Communications Equipment, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 2,000 |
Plant Area (Sq.Ft.) | 1,050,000 |
Annual Production | 500,000 Units |
Production Hrs. Annual | 7,300 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,631,434 | 33,155,832 | kWh | $0.05 |
Electricity Demand | $802,040 | 65,227 | kW-months/year | $12.30 |
Electricity Fees | $(-175,039) | - | $ | - |
TOTAL ENERGY COSTS | $2,367,506 | |||
RECOMMENDED SAVINGS* | $59,169 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7122 DISCONNECT BALLASTS |
Savings: $47,591 Cost: $5,500 |
$33,656 | 785,072 | $17,923 | 1,456 | $(-3,988) | - |
$33,656 785,072 kWh |
$17,923 1,456 kW-months/year |
$(-3,988) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $549 Cost: $845 |
$595 | 13,885 | - | - | $(-46) | - |
$595 13,885 kWh |
- - kW-months/year |
$(-46) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,386 Cost: $2,900 |
$2,802 | 49,304 | $825 | 67 | $(-241) | - |
$2,802 49,304 kWh |
$825 67 kW-months/year |
$(-241) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,557 Cost: $80 |
$2,824 | 49,678 | $986 | 80 | $(-253) | - |
$2,824 49,678 kWh |
$986 80 kW-months/year |
$(-253) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,086 Cost: $15,744 |
$4,428 | 103,297 | - | - | $(-342) | - |
$4,428 103,297 kWh |
- - kW-months/year |
$(-342) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $59,169 Cost: $25,069 |
$44,305 | 1,001,236 | $19,734 | 1,604 | $(-4,870) | - | $44,305 1,001,236 kWh |
$19,734 1,604 kW-months/year |