Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2021 |
Principal Product | automotive components |
NAICS | 336370 - Motor Vehicle Metal Stamping |
SIC | 3465 - Automotive Stampings |
Sales | $1,000,000-$5,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 420,000 |
Annual Production | 2,000,000 Units |
Production Hrs. Annual | 5,225 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $461,468 | 7,794,000 | kWh | $0.06 |
Electricity Demand | $93,735 | 11,937 | kW-months/year | $7.85 |
Electricity Fees | $47,945 | - | $ | - |
Natural Gas | $4,733 | 381 | MMBtu | $12.42 |
TOTAL ENERGY COSTS | $607,881 | |||
RECOMMENDED SAVINGS* | $72,464 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $52,277 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $6,816 Cost: $22,649 |
$6,274 | 105,959 | - | - | $542 | - |
$6,274 105,959 kWh |
- - kW-months/year |
$542 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $8,709 Cost: $24,348 |
$8,016 | 135,377 | - | - | $693 | - |
$8,016 135,377 kWh |
- - kW-months/year |
$693 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $45,219 Cost: $10,941 |
- | - | - | - | $45,219 | - |
- - kWh |
- - kW-months/year |
$45,219 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,058 Cost: $9,682 |
$5,498 | 92,850 | $999 | 127 | $561 | - |
$5,498 92,850 kWh |
$999 127 kW-months/year |
$561 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $2,529 Cost: $100 |
$2,328 | 39,297 | - | - | $201 | - |
$2,328 39,297 kWh |
- - kW-months/year |
$201 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,133 Cost: $4,930 |
$1,107 | 18,696 | $856 | 109 | $170 | - |
$1,107 18,696 kWh |
$856 109 kW-months/year |
$170 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $72,464 Cost: $72,650 |
$23,223 | 392,179 | $1,855 | 236 | $47,386 | - | $23,223 392,179 kWh |
$1,855 236 kW-months/year |
$47,386 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $52,277 Cost: $20,623 |
$5,498 | 92,850 | $999 | 127 | $45,780 | - | $5,498 92,850 kWh |
$999 127 kW-months/year |
$45,780 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |