Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2022 |
Principal Product | Printing Paper |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 45 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 7,400 Units |
Production Hrs. Annual | 5,355 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $95,207 | 925,560 | kWh | $0.10 |
Electricity Demand | $21,442 | 3,883 | kW-months/year | $5.52 |
Electricity Fees | $10,008 | - | $ | - |
TOTAL ENERGY COSTS | $126,657 | |||
RECOMMENDED SAVINGS* | $14,584 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,647 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,430 Cost: $1,362 |
$1,162 | 11,297 | $155 | 28 | $113 | - |
$1,162 11,297 kWh |
$155 28 kW-months/year |
$113 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $241 Cost: $540 |
$186 | 1,805 | $36 | 7 | $19 | - |
$186 1,805 kWh |
$36 7 kW-months/year |
$19 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,671 Cost: $1,000 |
$1,380 | 13,412 | $159 | 29 | $132 | - |
$1,380 13,412 kWh |
$159 29 kW-months/year |
$132 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,976 Cost: $5,978 |
$2,536 | 24,652 | $205 | 37 | $235 | - |
$2,536 24,652 kWh |
$205 37 kW-months/year |
$235 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7272 INSTALL HEAT PIPES / RAISE COOLING SETPOINT |
Savings: $8,266 Cost: $1,440 |
$7,613 | 74,010 | - | - | $653 | - |
$7,613 74,010 kWh |
- - kW-months/year |
$653 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $14,584 Cost: $10,320 |
$12,877 | 125,176 | $555 | 101 | $1,152 | - | $12,877 125,176 kWh |
$555 101 kW-months/year |
$1,152 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,647 Cost: $6,978 |
$3,916 | 38,064 | $364 | 66 | $367 | - | $3,916 38,064 kWh |
$364 66 kW-months/year |
$367 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |