Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2022 |
Principal Product | Organic Bread |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $5,000,000-$10,000,000 |
# of Employees | 170 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 47,000,000 Units |
Production Hrs. Annual | 8,736 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $312,109 | 5,343,000 | kWh | $0.06 |
Electricity Demand | $42,645 | 9,212 | kW-months/year | $4.63 |
Electricity Fees | $42,482 | - | $ | - |
Natural Gas | $351,471 | 27,075 | MMBtu | $12.98 |
TOTAL ENERGY COSTS | $748,707 | |||
RECOMMENDED SAVINGS* | $25,712 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,664 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $13,660 Cost: $51,749 |
$11,001 | 188,366 | $1,198 | 259 | $1,461 | - |
$11,001 188,366 kWh |
$1,198 259 kW-months/year |
$1,461 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,033 Cost: $1,000 |
$4,193 | 71,792 | $1,195 | 258 | $645 | - |
$4,193 71,792 kWh |
$1,195 258 kW-months/year |
$645 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,954 Cost: $1,360 |
$2,638 | 45,166 | - | - | $316 | - |
$2,638 45,166 kWh |
- - kW-months/year |
$316 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,388 Cost: $1,682 |
- | - | - | - | $2,388 | - |
- - kWh |
- - kW-months/year |
$2,388 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $677 Cost: $901 |
$605 | 10,353 | - | - | $72 | - |
$605 10,353 kWh |
- - kW-months/year |
$72 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,712 Cost: $56,692 |
$18,437 | 315,677 | $2,393 | 517 | $4,882 | - | $18,437 315,677 kWh |
$2,393 517 kW-months/year |
$4,882 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,664 Cost: $3,261 |
$7,436 | 127,311 | $1,195 | 258 | $1,033 | - | $7,436 127,311 kWh |
$1,195 258 kW-months/year |
$1,033 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |