Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2024 |
Principal Product | Infiltrator Systems |
NAICS | 326122 - Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084 - Plastics Pipe |
Sales | $5,000,000-$10,000,000 |
# of Employees | 22 |
Plant Area (Sq.Ft.) | 42,215 |
Annual Production | 14,436 Thousand Feet |
Production Hrs. Annual | 4,800 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $128,433 | 1,431,702 | kWh | $0.09 |
Electricity Demand | $29,442 | 6,173 | kW-months/year | $4.77 |
Electricity Fees | $32,954 | - | $ | - |
Natural Gas | $174,433 | 11,562 | MMBtu | $15.09 |
TOTAL ENERGY COSTS | $365,262 | |||
RECOMMENDED SAVINGS* | $108,172 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $81,410 Cost: $555,652 |
$66,372 | 739,933 | $981 | 206 | $14,057 | - | - | - |
$66,372 739,933 kWh |
$981 206 kW-months/year |
$14,057 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,200 Cost: $500 |
$1,608 | 17,927 | $212 | 44 | $380 | - | - | - |
$1,608 17,927 kWh |
$212 44 kW-months/year |
$380 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,530 Cost: $5,091 |
$1,175 | 13,098 | $91 | 19 | $264 | - | - | - |
$1,175 13,098 kWh |
$91 19 kW-months/year |
$264 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $6,760 Cost: $8,397 |
- | - | - | - | - | - | $6,760 | 448 |
- - kWh |
- - kW-months/year |
- - $ |
$6,760 448 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $5,137 Cost: $2,005 |
$3,952 | 44,055 | $298 | 62 | $887 | - | - | - |
$3,952 44,055 kWh |
$298 62 kW-months/year |
$887 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2441 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT |
Savings: $10,563 Cost: $56,271 |
- | - | - | - | - | - | $10,563 | 700 |
- - kWh |
- - kW-months/year |
- - $ |
$10,563 700 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $224 Cost: $224 |
$140 | 1,558 | $45 | 9 | $39 | - | - | - |
$140 1,558 kWh |
$45 9 kW-months/year |
$39 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $348 Cost: $452 |
$288 | 3,212 | - | - | $60 | - | - | - |
$288 3,212 kWh |
- - kW-months/year |
$60 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $108,172 Cost: $628,592 |
$73,535 | 819,783 | $1,627 | 340 | $15,687 | - | $17,323 | 1,148 | $73,535 819,783 kWh |
$1,627 340 kW-months/year |
$15,687 - $ |
$17,323 1,148 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |