IAC logo
IAC Assessment: UA3022
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UA3022
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Alabama
Assessment Year 2012
Principal Product Aluminum Ingots
NAICS 332322 - Sheet Metal Work Manufacturing
SIC 3444 - Sheet Metalwork
Sales >$500,000,000
# of Employees 900
Plant Area (Sq.Ft.) 4,356,000
Annual Production 831,225,988 Pounds
Production Hrs. Annual 8,760
Location (State) AL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $12,971,789 393,954,353 kWh $0.03
Electricity Demand $11,321,826 759,527 kW-months/year $14.91
TOTAL ENERGY COSTS $24,293,615
RECOMMENDED SAVINGS* $162,826 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$54,140
Cost:
$50
$33,385 1,013,820 $20,755 1,392 $33,385
1,013,820
kWh
$20,755
1,392
kW-months/year
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$31,511
Cost:
$15,063
$19,419 589,698 $12,092 811 $19,419
589,698
kWh
$12,092
811
kW-months/year
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$12,180
Cost:
$50
$7,528 228,620 $4,652 312 $7,528
228,620
kWh
$4,652
312
kW-months/year
04: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$64,995
Cost:
$90,750
$40,125 1,218,500 $24,870 1,668 $40,125
1,218,500
kWh
$24,870
1,668
kW-months/year
TOTAL RECOMMENDED Savings:
$162,826
Cost:
$105,913
$100,457 3,050,638 $62,369 4,183 $100,457
3,050,638
kWh
$62,369
4,183
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand