Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2013 |
Principal Product | Refurbishing Vacuum Pumps |
NAICS | 333912 - Air and Gas Compressor Manufacturing |
SIC | 3563 - Air And Gas Compressors |
Sales | $5,000,000-$10,000,000 |
# of Employees | 10 |
Plant Area (Sq.Ft.) | 20,000 |
Annual Production | 250 Units |
Production Hrs. Annual | 3,276 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,435 | 296,480 | kWh | $0.10 |
Electricity Demand | $35,341 | 5,999 | kW-months/year | $5.89 |
Electricity Fees | $4,441 | - | $ | - |
Natural Gas | $10,835 | 829 | MMBtu | $13.07 |
TOTAL ENERGY COSTS | $91,782 | |||
RECOMMENDED SAVINGS* | $17,518 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $3,385 Cost: $8,470 |
- | - | - | - | - | - | $3,385 | 259 |
- - kWh |
- - kW-months/year |
- - $ |
$3,385 259 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $978 Cost: $330 |
$208 | 2,026 | - | - | $12 | - | $758 | 58 |
$208 2,026 kWh |
- - kW-months/year |
$12 - $ |
$758 58 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $5,732 Cost: $15,725 |
$4,329 | 42,151 | $1,090 | 185 | $313 | - | - | - |
$4,329 42,151 kWh |
$1,090 185 kW-months/year |
$313 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,525 Cost: $400 |
$1,110 | 10,811 | $332 | 56 | $83 | - | - | - |
$1,110 10,811 kWh |
$332 56 kW-months/year |
$83 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $5,898 Cost: $6,420 |
- | - | $5,575 | 1,176 | $323 | - | - | - |
- - kWh |
$5,575 1,176 kW-months/year |
$323 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $17,518 Cost: $31,345 |
$5,647 | 54,988 | $6,997 | 1,417 | $731 | - | $4,143 | 317 | $5,647 54,988 kWh |
$6,997 1,417 kW-months/year |
$731 - $ |
$4,143 317 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |