Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Connecticut |
---|---|
Assessment Year | 2022 |
Principal Product | Static metal seals |
NAICS | 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing |
SIC | 3699 - Electrical Equipment & Supplies, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 171 |
Plant Area (Sq.Ft.) | 55,000 |
Annual Production | 100,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $354,633 | 3,174,060 | kWh | $0.11 |
Electricity Demand | $265,876 | 16,023 | kW-months/year | $16.59 |
Electricity Fees | $5,004 | - | $ | - |
Natural Gas | $62,305 | 6,779 | MMBtu | $9.19 |
TOTAL ENERGY COSTS | $687,818 | |||
RECOMMENDED SAVINGS* | $166,178 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,768 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $21,740 Cost: $114,471 |
$7,891 | 70,645 | $738 | 45 | $13,111 | - |
$7,891 70,645 kWh |
$738 45 kW-months/year |
$13,111 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,684 Cost: $2,000 |
$6,257 | 56,016 | $1,427 | 86 | - | - |
$6,257 56,016 kWh |
$1,427 86 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $322 Cost: $960 |
$264 | 2,359 | $58 | 4 | - | - |
$264 2,359 kWh |
$58 4 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,344 Cost: $200 |
$1,109 | 9,930 | $234 | 14 | - | - |
$1,109 9,930 kWh |
$234 14 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $135,088 Cost: $543,322 |
$100,274 | 897,704 | $46,198 | 2,784 | $(-11,383) | - |
$100,274 897,704 kWh |
$46,198 2,784 kW-months/year |
$(-11,383) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $166,178 Cost: $660,953 |
$115,794 | 1,036,654 | $48,655 | 2,932 | $1,728 | - | $115,794 1,036,654 kWh |
$48,655 2,932 kW-months/year |
$1,728 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,768 Cost: $116,671 |
$15,257 | 136,591 | $2,400 | 145 | $13,111 | - | $15,257 136,591 kWh |
$2,400 145 kW-months/year |
$13,111 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes |