Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Connecticut |
---|---|
Assessment Year | 2024 |
Principal Product | Automatic doors |
NAICS | 332321 - Metal Window and Door Manufacturing |
SIC | 3442 - Metal Doors, Sash, And Trim |
Sales | $50,000,000-$100,000,000 |
# of Employees | 222 |
Plant Area (Sq.Ft.) | 155,000 |
Annual Production | 1,000,000 Units |
Production Hrs. Annual | 5,100 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $264,825 | 1,172,185 | kWh | $0.23 |
Electricity Demand | $45,668 | 1,799 | kW-months/year | $25.39 |
Electricity Fees | $17,952 | - | $ | - |
Natural Gas | $5,902 | 393 | MMBtu | $15.01 |
LPG | $2,027 | 83 | MMBtu | $24.33 |
TOTAL ENERGY COSTS | $336,374 | |||
RECOMMENDED SAVINGS* | $149,147 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $187 Cost: - |
- | - | - | - | $187 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$187 - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $4,304 Cost: - |
- | - | - | - | $4,304 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,304 - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $71,178 Cost: $259,330 |
$75,394 | 333,752 | - | - | - | - | - | - | - | - | $(-4,216) | - | - | - |
$75,394 333,752 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$(-4,216) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $5,106 Cost: $816 |
$819 | 3,627 | - | - | - | - | $4,286 | 286 | - | - | - | - | - | - |
$819 3,627 kWh |
- - kW-months/year |
- - $ |
$4,286 286 MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,973 Cost: $75 |
$1,662 | 7,357 | $311 | 12 | - | - | - | - | - | - | - | - | - | - |
$1,662 7,357 kWh |
$311 12 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $6,293 Cost: $60 |
$6,293 | 27,857 | - | - | - | - | - | - | - | - | - | - | - | - |
$6,293 27,857 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,445 Cost: $1,300 |
$2,901 | 12,842 | $543 | 21 | - | - | - | - | - | - | - | - | - | - |
$2,901 12,842 kWh |
$543 21 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $6,458 Cost: $61,975 |
$(-3,271) | (-14,482) | $10,156 | 400 | - | - | - | - | $(-427) | - | - | - | - | - |
$(-3,271) (-14,482) kWh |
$10,156 400 kW-months/year |
- - $ |
- - MMBtu |
$(-427) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $33,101 Cost: $341,537 |
$(-25,842) | (-114,396) | $(-3,979) | (-157) | - | - | $62,922 | 4,192 | - | - | - | - | - | - |
$(-25,842) (-114,396) kWh |
$(-3,979) (-157) kW-months/year |
- - $ |
$62,922 4,192 MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $17,102 Cost: $30,000 |
- | - | $(-42,011) | (-1,655) | - | - | - | - | - | - | - | - | $59,113 | - |
- - kWh |
$(-42,011) (-1,655) kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
$59,113 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $149,147 Cost: $695,093 |
$57,956 | 256,557 | $(-34,979) | (-1,378) | $4,491 | - | $67,208 | 4,478 | $(-427) | - | $(-4,216) | - | $59,113 | - | $57,956 256,557 kWh |
$(-34,979) (-1,378) kW-months/year |
$4,491 - $ |
$67,208 4,478 MMBtu |
$(-427) - $ |
$(-4,216) - $ |
$59,113 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |