Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1989
Principal Product GEAR BOX & MOTOR DRIVES
NAICS n/a
SIC 3566 - Speed Changers, Drives, And Gears
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 0
Annual Production 25,000 Pieces
Production Hrs. Annual 2,100
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $45,482 640,094 kWh $0.07
Natural Gas $10,300 2,396 MMBtu $4.30
TOTAL ENERGY COSTS $55,782
RECOMMENDED SAVINGS* $10,334 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,549
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$2,548
Cost:
$6,000
$3,111 29,015 $(-563) (-137) $3,111
29,015
kWh
$(-563)
(-137)
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$2,832
Cost:
$15,000
$3,457 32,532 $(-625) (-147) $3,457
32,532
kWh
$(-625)
(-147)
MMBtu
03: 2.2532 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD Savings:
$851
Cost:
$500
$105 4,396 $746 176 $105
4,396
kWh
$746
176
MMBtu
04: 2.7245 USE DIRECT AIR SUPPLY TO EXHAUST HOODS Savings:
$2,237
Cost:
$4,000
$247 10,258 $1,990 469 $247
10,258
kWh
$1,990
469
MMBtu
05: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,866
Cost:
$2,000
$1,866 - - - $1,866
-
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$10,334
Cost:
$27,500
$8,786 76,201 $1,548 361 $8,786
76,201
kWh
$1,548
361
MMBtu
TOTAL IMPLEMENTED Savings:
$5,549
Cost:
$17,500
$5,428 36,928 $121 29 $5,428
36,928
kWh
$121
29
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas