Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2001
Principal Product Custom blow molded plastic parts
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 115
Plant Area (Sq.Ft.) 85,000
Annual Production 10,000,000 Pounds
Production Hrs. Annual 8,568
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $351,785 9,230,400 kWh $0.04
Electricity Demand $175,352 17,448 kW-months/year $10.05
Natural Gas $3,406 380 MMBtu $8.96
TOTAL ENERGY COSTS $540,317
RECOMMENDED SAVINGS* $65,253 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $52,076
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Liquid (non-haz) Electricity Usage Electricity Demand Other Liquid (non-haz)
$ kWh $ kW-months/year $ gal
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$22,708
Cost:
$55,000
$15,870 377,849 $6,838 680 - - $15,870
377,849
kWh
$6,838
680
kW-months/year
-
-
gal
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$12,972
Cost:
$315
$9,716 231,336 $3,256 324 - - $9,716
231,336
kWh
$3,256
324
kW-months/year
-
-
gal
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$10,095
Cost:
$4,500
$7,562 180,050 $2,533 252 - - $7,562
180,050
kWh
$2,533
252
kW-months/year
-
-
gal
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,767
Cost:
$13,700
$7,778 185,182 $989 98 - - $7,778
185,182
kWh
$989
98
kW-months/year
-
-
gal
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$5,466
Cost:
$2,880
$4,048 96,390 $1,418 135 - - $4,048
96,390
kWh
$1,418
135
kW-months/year
-
-
gal
06: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$3,363
Cost:
$100
$2,519 59,976 $844 84 - - $2,519
59,976
kWh
$844
84
kW-months/year
-
-
gal
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,047
Cost:
$3,000
$655 15,600 $392 156 - - $655
15,600
kWh
$392
156
kW-months/year
-
-
gal
08: 3.5112 REPROCESS SPENT OILS ON SITE FOR RE-USE Savings:
$835
Cost:
$3,323
- - - - $835 325 -
-
kWh
-
-
kW-months/year
$835
325
gal
TOTAL RECOMMENDED Savings:
$65,253
Cost:
$82,818
$48,148 1,146,383 $16,270 1,729 $835 325 $48,148
1,146,383
kWh
$16,270
1,729
kW-months/year
$835
325
gal
TOTAL IMPLEMENTED Savings:
$52,076
Cost:
$66,018
$37,196 885,625 $14,045 1,391 $835 325 $37,196
885,625
kWh
$14,045
1,391
kW-months/year
$835
325
gal
Savings
Cost
$ kWh $ kW-months/year $ gal
Electricity Usage Electricity Demand Other Liquid (non-haz) Electricity Usage Electricity Demand Other Liquid (non-haz)